EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cryogenic geometric anti-spring vibration isolation system

L Feenstra, S Domínguez-Calderón, K van Oosten, H S M van Bohemen, T Benschop, M T Brinkman, M Li, E Hennes, R Cornelissen, B J Hensen, A Bertolini, M P Allan

Measurement Science and Technology · 20.03.2026 · 37 (13) · 135001

DOI: 10.1088/1361-6501/ae5404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 31.03.2026. Verfasst von L Feenstra und 11 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The combination of low temperature and low vibration levels is key for ultrasensitive sensing applications such as scanning probe microscopy, large-mass quantum mechanics, and gravitational wave detection. Unfortunately, closed-cycle cryostats using pulse tube or GM coolers introduce strong low-frequency vibrations starting at 1 Hz. Mass-spring systems allow passive isolation, but for low-frequency applications the required spring constants and masses become impractical. Blade-based geometric anti-spring (GAS) systems are compact isolators that operate from sub-Hz frequencies, but have not been demonstrated at cryogenic temperatures. Here, we characterize a GAS system tuned to operate at cryogenic temperatures. Our cryogenic filter uses radially arranged titanium blade springs whose effective spring constant can be tuned in-situ using a magnetic actuator. Our system achieves a vertical resonance frequency of 185 mHz at 7 K, which allows reduction of vibrations at the problematic 1 Hz cooler frequency by 8 dB.

Förderung

  • European Research Council

Zitieren

APA

Feenstra, L., Domínguez-Calderón, S., Oosten, K. V., Bohemen, H. S. M. V., Benschop, T., Brinkman, M. T., Li, M., Hennes, E., Cornelissen, R., Hensen, B. J., Bertolini, A., & Allan, M. P. (2026). Cryogenic geometric anti-spring vibration isolation system. Measurement Science and Technology, 37(13), 135001. https://doi.org/10.1088/1361-6501/ae5404

Vancouver

Feenstra L, Domínguez-Calderón S, Oosten KV, Bohemen HSMV, Benschop T, Brinkman MT, et al. Cryogenic geometric anti-spring vibration isolation system. Measurement Science and Technology. 2026;37(13):135001. doi:10.1088/1361-6501/ae5404

BibTeX
@article{Feenstra2026,
  author = {Feenstra, L and Domínguez-Calderón, S and Oosten, K van and Bohemen, H S M van and Benschop, T and Brinkman, M T and Li, M and Hennes, E and Cornelissen, R and Hensen, B J and Bertolini, A and Allan, M P},
  title = {Cryogenic geometric anti-spring vibration isolation system},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {13},
  pages = {135001},
  doi = {10.1088/1361-6501/ae5404}
}
Kostenlos starten →