EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Constant radius blade spring suspended bench for vibration isolation

Koh A Baker iD, John Winterflood iD, Carl Blair iD, Chiara Di Fronzo iD, Li Ju iD, Chunnong Zhao iD

Review of Scientific Instruments · 01.07.2026 · 97 (7)

DOI: 10.1063/5.0333474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 02.07.2026. Verfasst von Koh A Baker und 5 weiteren Autor:innen. Beteiligte Einrichtung: Australian Research Council Centre of Excellence for Gravitational Wave Discovery (OzGrav), University of Western Australia, Perth, Western Australia…. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council Centre of Excellence or Gravitational Wave Discovery, Australian Government Research Training Program Scholarship.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-precision measurements are typically isolated from ground motion to reduce seismic noise interference. We introduce a passive, spring-suspended optics bench for use inside a tabletop vacuum tank. The isolator uses four initially flat cantilever blade springs, loaded to a constant radius of curvature, to attenuate vertical motion. This type of constant curvature blade spring has the advantage of minimizing horizontal–vertical cross coupling around its suspension resonance frequency compared to other blade springs. We use finite element modeling to optimize the geometry of the constant radius blade spring toward maximizing its vertical isolation. We validate our modeled constant curvature blade results using an experimental shaker table setup, with geophone sensing. Our suspension bench achieves a vertical attenuation bandwidth of 3–90 Hz with horizontal–vertical cross coupling below −50 dB in the frequency range of 7–90 Hz. Using our model, we found that the cross coupling of the constant curvature blade spring is outperformed at higher frequencies by a pre-bent blade spring, which is flat at its operating point.

Autor:innen und Institutionen

  • Australian Research Council Centre of Excellence for Gravitational Wave Discovery (OzGrav), University of Western Australia, Perth, Western Australia, Australia.

ORCID-Profile: Koh A Baker, John Winterflood, Carl Blair, Chiara Di Fronzo, Li Ju, Chunnong Zhao

Förderung

  • Australian Research Council Centre of Excellence or Gravitational Wave Discovery
  • Australian Government Research Training Program Scholarship

Zitieren

APA

Baker, K. A., Winterflood, J., Blair, C., Di Fronzo, C., Ju, L., & Zhao, C. (2026). Constant radius blade spring suspended bench for vibration isolation. Review of Scientific Instruments, 97(7). https://doi.org/10.1063/5.0333474

Vancouver

Baker KA, Winterflood J, Blair C, Di Fronzo C, Ju L, Zhao C. Constant radius blade spring suspended bench for vibration isolation. Review of Scientific Instruments. 2026;97(7). doi:10.1063/5.0333474

BibTeX
@article{Baker2026,
  author = {Baker, Koh A and Winterflood, John and Blair, Carl and Di Fronzo, Chiara and Ju, Li and Zhao, Chunnong},
  title = {Constant radius blade spring suspended bench for vibration isolation},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {7},
  doi = {10.1063/5.0333474}
}
Kostenlos starten →