EUVIMEDEUVIMED entdecken
Crossref

Hysteresis and loss characteristics of Fe-based nanocrystalline alloys based on a novel variable-temperature dynamic Jiles–Atherton hysteresis model

Xueping Xu, Zhenkai Zhao, Jianyi Ren, Danyue Ma

Journal of Physics D: Applied Physics · 01.03.2024 · 57 (9) · 095001

DOI: 10.1088/1361-6463/ad0fbc ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Physics D: Applied Physics, online erschienen am 01.12.2023. Verfasst von Xueping Xu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Innovation Program for Quantum Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The magnetic characteristics of Fe-based nanocrystalline alloys can be influenced by temperature. The conventional dynamic Jiles–Atherton (J-A) hysteresis model does not take into consideration the impact that temperature has on magnetic characteristics. A novel variable-temperature dynamic J-A hysteresis model is proposed in this paper to effectively address the issue. Firstly, the hysteresis loops of Fe-based nanocrystalline are measured at −50 °C–130 °C and DC state. The five parameters of the J-A hysteresis model are identified at various temperatures using the particle swarm optimization algorithm, and five parameters are fitted as functions of temperature. Subsequently, the five parameters as functions of temperature are introduced into the conventional dynamic J-A hysteresis model to construct a novel variable-temperature dynamic J-A hysteresis model, which can not only reflect the impact of temperature but also accurately calculate the losses. Finally, hysteresis loops and losses of Fe-based nanocrystalline alloy are simulated and calculated at different temperatures and frequencies by the variable-temperature dynamic J-A hysteresis model. Meanwhile, this paper also investigates the trends and percentages of hysteresis loss, excess loss as well as eddy current loss with frequency and temperature. Compared to the results of measured data, the maximum average error of the variable-temperature dynamic J-A hysteresis model is 5.83%.

Förderung

  • National Natural Science Foundation of China
  • Innovation Program for Quantum Science and Technology

Zitieren

APA

Xu, X., Zhao, Z., Ren, J., & Ma, D. (2024). Hysteresis and loss characteristics of Fe-based nanocrystalline alloys based on a novel variable-temperature dynamic Jiles–Atherton hysteresis model. Journal of Physics D: Applied Physics, 57(9), 095001. https://doi.org/10.1088/1361-6463/ad0fbc

Vancouver

Xu X, Zhao Z, Ren J, Ma D. Hysteresis and loss characteristics of Fe-based nanocrystalline alloys based on a novel variable-temperature dynamic Jiles–Atherton hysteresis model. Journal of Physics D: Applied Physics. 2024;57(9):095001. doi:10.1088/1361-6463/ad0fbc

BibTeX
@article{Xu2024,
  author = {Xu, Xueping and Zhao, Zhenkai and Ren, Jianyi and Ma, Danyue},
  title = {Hysteresis and loss characteristics of Fe-based nanocrystalline alloys based on a novel variable-temperature dynamic Jiles–Atherton hysteresis model},
  journal = {Journal of Physics D: Applied Physics},
  year = {2024},
  volume = {57},
  number = {9},
  pages = {095001},
  doi = {10.1088/1361-6463/ad0fbc}
}
Kostenlos starten →