EUVIMEDEUVIMED entdecken
Crossref

A three-stage demagnetization method based on quantified irreversible permeability and a dynamic hysteresis parameter Jiles–Atherton model

Yuzheng Ma, Minxia Shi, Yusen Li, Leran Zhang, Shuai Yuan, Gang Liu

Journal of Physics D: Applied Physics · 19.06.2026 · 59 (24) · 245003

DOI: 10.1088/1361-6463/ae69f5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Physics D: Applied Physics, online erschienen am 19.06.2026. Verfasst von Yuzheng Ma und 5 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Gefördert von: the National Double First-class Special Foundation of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High performance magnetic shielding is necessary in the fields of high-precision measurement based on quantum sensors such as biological magnetic field. Demagnetization is one of the most prevalent techniques employed to enhance the performance of a magnetically shielded room (MSR). This paper proposes a three-stage demagnetization method based on the quantification of incremental irreversible permeability and the dynamic hysteresis parameter JA(DHP-JA) model. The method is developed from the fundamental perspective of demagnetization theory. First, a quantitative indicator is introduced to characterize the irreversible magnetization, which is the primary target in demagnetization. Second, the dynamic variation of hysteresis parameters with magnetization state is realized through a combination of physical formula derivation and parameter fitting. Finally, by integrating the irreversible magnetization indicator with the DHP-JA model, the three-stage demagnetization method is applied to MSRs, achieving an optimized time distribution among the three stages. As a result, the residual field at the center of a single-layer box-type MSR with dimensions of 420 mm × 420 mm × 420 mm and 2 mm thickness is reduced to 0.4 nT, representing a 58% reduction compared with the conventional optimal method. For a more complex tooth-type MSR, the proposed three-stage demagnetization method reduces the central residual field by 31.3% relative to the conventional approach.

Förderung

  • the National Double First-class Special Foundation of China
  • National Natural Science Foundation of China

Zitieren

APA

Ma, Y., Shi, M., Li, Y., Zhang, L., Yuan, S., & Liu, G. (2026). A three-stage demagnetization method based on quantified irreversible permeability and a dynamic hysteresis parameter Jiles–Atherton model. Journal of Physics D: Applied Physics, 59(24), 245003. https://doi.org/10.1088/1361-6463/ae69f5

Vancouver

Ma Y, Shi M, Li Y, Zhang L, Yuan S, Liu G. A three-stage demagnetization method based on quantified irreversible permeability and a dynamic hysteresis parameter Jiles–Atherton model. Journal of Physics D: Applied Physics. 2026;59(24):245003. doi:10.1088/1361-6463/ae69f5

BibTeX
@article{Ma2026,
  author = {Ma, Yuzheng and Shi, Minxia and Li, Yusen and Zhang, Leran and Yuan, Shuai and Liu, Gang},
  title = {A three-stage demagnetization method based on quantified irreversible permeability and a dynamic hysteresis parameter Jiles–Atherton model},
  journal = {Journal of Physics D: Applied Physics},
  year = {2026},
  volume = {59},
  number = {24},
  pages = {245003},
  doi = {10.1088/1361-6463/ae69f5}
}
Kostenlos starten →