Optimizing sensor placement in classrooms: a focus on temperature, relative humidity and CO 2

Maria-Angels Llabres-Morey, Susana Hormigos-Jimenez, Mercedes Del Río Merino, Veronica Vitiello

Advances in Building Energy Research · 04.07.2026 · 20 (4) · 586-610

DOI: 10.1080/17512549.2026.2638472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Building Energy Research, online erschienen am 03.03.2026. Verfasst von Maria-Angels Llabres-Morey und 3 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In developed countries, people spend most of their time indoors; therefore, indoor environmental quality has a direct impact on human health. Assessing indoor conditions requires the continuous monitoring of several parameters. In this context, the present study aims to analyze the influence of sensor placement on the monitoring of CO2 concentration, temperature and relative humidity in a primary school classroom. To this end, several sensors were installed in different locations within the classroom, and real-time data were collected for CO2 concentration, temperature and relative humidity. The results showed that CO2 measurements exhibited deviations from the mean ranging from 1% to 11% depending on sensor position, with the highest concentrations recorded near the students’ working area. In contrast, deviations in temperature and relative humidity were minimal, ranging between 1–3% and 0–5%, respectively. It is concluded that the most appropriate location for sensor placement in this type of study is on the teacher’s desk, as it allows for minimal interference with teaching activities, facilitates teacher supervision of the device, is positioned near the main emission source, ensures proper sensor operation, and yields representative data of the classroom environment in terms of CO2, temperature and relative humidity.

Zitieren

APA

Llabres-Morey, M., Hormigos-Jimenez, S., Merino, M. D. R., & Vitiello, V. (2026). Optimizing sensor placement in classrooms: a focus on temperature, relative humidity and CO 2. Advances in Building Energy Research, 20(4), 586-610. https://doi.org/10.1080/17512549.2026.2638472

Vancouver

Llabres-Morey M, Hormigos-Jimenez S, Merino MDR, Vitiello V. Optimizing sensor placement in classrooms: a focus on temperature, relative humidity and CO 2. Advances in Building Energy Research. 2026;20(4):586-610. doi:10.1080/17512549.2026.2638472

BibTeX
@article{LlabresMorey2026,
  author = {Llabres-Morey, Maria-Angels and Hormigos-Jimenez, Susana and Merino, Mercedes Del Río and Vitiello, Veronica},
  title = {Optimizing sensor placement in classrooms: a focus on temperature, relative humidity and CO 2},
  journal = {Advances in Building Energy Research},
  year = {2026},
  volume = {20},
  number = {4},
  pages = {586--610},
  doi = {10.1080/17512549.2026.2638472}
}
Kostenlos starten →