Digital Pupillometry in Normal Subjects
Neuro-Ophthalmology · 02.01.2017 · 41 (1) · 12-18
DOI: 10.1080/01658107.2016.1226345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neuro-Ophthalmology, online erschienen am 03.10.2016. Verfasst von Annekatrin Rickmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Knappschaft Eye Clinic Sulzbach, Knappschaft Hospital Saar , Sulzbach/Saar, Germany. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The aim of this study was to evaluate the pupil size of normal subjects at different illumination levels with a novel pupillometer. The pupil size of healthy study participants was measured with an infrared-video PupilX pupillometer (MEye Tech GmbH, Alsdorf, Germany) at five different illumination levels (0, 0.5, 4, 32, and 250 lux). Measurements were performed by the same investigator. Ninety images were executed during a measurement period of 3 seconds. The absolute linear camera resolution was approximately 20 pixels per mm. This cross-sectional study analysed 490 eyes of 245 subjects (mean age: 51.9 ± 18.3 years, range: 6-87 years). On average, pupil diameter decreased with increasing light intensities for both eyes, with a mean pupil diameter of 5.39 ± 1.04 mm at 0 lux, 5.20 ± 1.00 mm at 0.5 lux, 4.70 ± 0.97 mm at 4 lux, 3.74 ± 0.78 mm at 32 lux, and 2.84 ± 0.50 mm at 250 lux illumination. Furthermore, it was found that anisocoria increased by 0.03 mm per life decade for all illumination levels (R2 = 0.43). Anisocoria was higher under scotopic and mesopic conditions. This study provides additional information to the current knowledge concerning age- and light-related pupil size and anisocoria as a baseline for future patient studies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Knappschaft Eye Clinic Sulzbach, Knappschaft Hospital Saar , Sulzbach/Saar, Germany.
- Knappschaft Eye Clinic Sulzbach, Knappschaft Hospital Saar, Sulzbach/Saar, Germany; University Eye Clinic Tübingen, Centre for Ophthalmology, Tübingen, Germany.
- University Eye Clinic Tübingen, Centre for Ophthalmology , Tübingen, Germany.
Zitieren
APA
Rickmann, A., Waizel, M., Kazerounian, S., Szurman, P., Wilhelm, H., & Boden, K. T. (2017). Digital Pupillometry in Normal Subjects. Neuro-Ophthalmology, 41(1), 12-18. https://doi.org/10.1080/01658107.2016.1226345
Vancouver
Rickmann A, Waizel M, Kazerounian S, Szurman P, Wilhelm H, Boden KT. Digital Pupillometry in Normal Subjects. Neuro-Ophthalmology. 2017;41(1):12-18. doi:10.1080/01658107.2016.1226345
BibTeX
@article{Rickmann2017,
author = {Rickmann, Annekatrin and Waizel, Maria and Kazerounian, Sara and Szurman, Peter and Wilhelm, Helmut and Boden, Karl T},
title = {Digital Pupillometry in Normal Subjects},
journal = {Neuro-Ophthalmology},
year = {2017},
volume = {41},
number = {1},
pages = {12--18},
doi = {10.1080/01658107.2016.1226345}
}