Digital Pupillometry and Centroid Shift Changes in Dominant and Nondominant Eyes
Klinische Monatsblätter für Augenheilkunde · 01.01.2025 · 242 (01) · 62-69
DOI: 10.1055/a-2184-4260 ↗Kurz gefasst
Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.01.2025. Verfasst von Wenhao Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology, Fuyang People's Hospital of Anhui Medical University, Fuyang, China. Hauptthemen laut MEDLINE: Pupil, Myopia, Dominance, Ocular, Keratomileusis, Laser In Situ. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To investigate the differences between dominant and nondominant eyes in a predominantly young patient population by analyzing the angle kappa, pupil size, and center position in dominant and nondominant eyes.
Methods
A total of 126 young college students (252 eyes) with myopia who underwent femtosecond laser-combined LASIK were randomly selected. Ocular dominance was determined using the hole-in-card test. The WaveLight Allegro Topolyzer (WaveLight Laser Technologies AG, Erlangen, Germany) was used to measure the pupil size and center position. The offset between the pupil center and the coaxially sighted corneal light reflex (P-Dist) of the patients was recorded by the x- and y-axis eyeball tracking adjustment program of the WaveLight Eagle Vision EX500 excimer laser system (Wavelight GmbH). The patientʼs vision (uncorrected distance visual acuity [UDVA], best-corrected visual acuity (BCVA), and refractive power (spherical equivalent, SE) were observed preoperatively, 1 week, 4 weeks, and 12 weeks postoperatively, and a quality of vision (QoV) questionnaire was completed.
Results
Ocular dominance occurred predominantly in the right eye [right vs. left: (178) 70.63% vs. (74) 29.37%; p < 0.001]. The P-Dist was 0.202 ± 0.095 mm in the dominant eye and 0.215 ± 0.103 mm in the nondominant eye (p = 0.021). The horizontal pupil shift was − 0.07 ± 0.14 mm in dominant eyes and 0.01 ± 0.13 mm in nondominant eyes (p = 0.001) (the temporal displacement of the dominant eye under mesopic conditions). The SE was negatively correlated with the P-Dist (r = − 0.223, p = 0.012 for the dominant eye and r = − 0.199, p = 0.025 for the nondominant eye). At 12 weeks postoperatively, the safety index (postoperative BDVA/preoperative BDVA) of the dominant and nondominant eyes was 1.20 (1.00, 1.22) and 1.20 (1.00, 1.20), respectively, and the efficacy index (postoperative UDVA/preoperative BDVA) was 1.00 (1.00, 1.20) and 1.00 (1.00, 1.20), respectively; the proportion of residual SE within ± 0.50 D was 98 and 100%, respectively.
Conclusions
This study found that ocular dominance occurred predominantly in the right eye. The pupil size change was larger in the dominant eye. The angle kappa of the dominant eye was smaller than that of the nondominant eye and the pupil center of the dominant eye was slightly shifted to the temporal side under mesopic conditions. The correction of myopia in the dominant and nondominant eyes exhibits good safety, efficacy, and predictability in the short term after surgery, and has good subjective visual quality performance after correction. We suggest adjusting the angle kappa percentage in the dominant eye to be lower than that of the nondominant eye in individualized corneal refractive surgery in order to find the ablation center closest to the visual axis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Ophthalmology, Fuyang People's Hospital of Anhui Medical University, Fuyang, China.
- Ophthalmology, Enshi Huiyi Ophthalmology Hospital, Enshi, China.
- Ophthalmology, Yanbian University Hospital, Yanji, China.
- Xiangya School of Medicine, Central South University, Changsha, China.
- Ophthalmology, Ningde Municipal Hospital of Ningde Normal University, Ningde, China.
- Ophthalmology, Zaozhuang Municipal Hospital, Zaozhuang, China.
ORCID-Profile: Wenhao Xu
Zitieren
APA
Xu, W., Jia, F., Liu, J., Li, J., Zhao, J., Lin, S., Jia, Y., & Li, Y. (2025). Digital Pupillometry and Centroid Shift Changes in Dominant and Nondominant Eyes. Klinische Monatsblätter für Augenheilkunde, 242(01), 62-69. https://doi.org/10.1055/a-2184-4260
Vancouver
Xu W, Jia F, Liu J, Li J, Zhao J, Lin S, et al. Digital Pupillometry and Centroid Shift Changes in Dominant and Nondominant Eyes. Klinische Monatsblätter für Augenheilkunde. 2025;242(01):62-69. doi:10.1055/a-2184-4260
BibTeX
@article{Xu2025,
author = {Xu, Wenhao and Jia, Fali and Liu, Jingting and Li, Jiahao and Zhao, Jian and Lin, Shuhua and Jia, Yujie and Li, Yingjun},
title = {Digital Pupillometry and Centroid Shift Changes in Dominant and Nondominant Eyes},
journal = {Klinische Monatsblätter für Augenheilkunde},
year = {2025},
volume = {242},
number = {01},
pages = {62--69},
doi = {10.1055/a-2184-4260}
}
EUVIMED