EUVIMEDEUVIMED entdecken
Crossref

A rapid method for the analysis of perfluorinated alkyl substances in serum by hybrid solid-phase extraction

Masato Honda, Morgan Robinson, Kurunthachalam Kannan

Environmental Chemistry · 29.05.2018 · 15 (2) · 92-99

DOI: 10.1071/en17192 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Chemistry, online erschienen am 08.05.2018. Verfasst von Masato Honda und 2 weiteren Autor:innen. Die Arbeit wurde bisher 69-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Environmental context Although the environmental occurrence of perfluoroalkyl substances was first reported almost 20 years ago, there are continuing concerns about human exposure to these potentially toxic chemicals. Such concerns have necessitated the development of reliable methods for rapid determination of perfluoroalkyl substances in human serum. This article describes a rapid and sensitive analytical method suitable for monitoring human exposure to perfluoroalkyl substances. Abstract A method for the analysis of 13 perfluorinated alkyl substances (PFASs) in human serum was developed based on hybrid solid-phase extraction (hybrid-SPE) and ultrahigh-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS). Serum PFASs were extracted using hybrid-SPE-phospholipid cartridge after precipitating proteins and other endogenous biological interferences with 1 % ammonium formate in methanol. The average intra-day accuracy (measured as percent recoveries from fortified samples) and precision of the method (measured as relative standard deviation [RSD, %] between analyses) were 88.7–117 % and 1.0–13.4 %, respectively. The average inter-day precision was 2.8–6.9 %. The method was sensitive, with limits of quantification (LOQs) in the range of 0.05 to 0.09 ng mL-1 for all 13 PFASs. The applicability of this method was tested by analysing serum-certified standard reference material and proficiency test samples. In an hour, 100 samples can be processed by hybrid-SPE, and the instrumental run time is 5 min per sample. The developed method is rapid, inexpensive, accurate, precise, and extremely sensitive for the analysis of PFASs in human serum.

Zitieren

APA

Honda, M., Robinson, M., & Kannan, K. (2018). A rapid method for the analysis of perfluorinated alkyl substances in serum by hybrid solid-phase extraction. Environmental Chemistry, 15(2), 92-99. https://doi.org/10.1071/en17192

Vancouver

Honda M, Robinson M, Kannan K. A rapid method for the analysis of perfluorinated alkyl substances in serum by hybrid solid-phase extraction. Environmental Chemistry. 2018;15(2):92-99. doi:10.1071/en17192

BibTeX
@article{Honda2018,
  author = {Honda, Masato and Robinson, Morgan and Kannan, Kurunthachalam},
  title = {A rapid method for the analysis of perfluorinated alkyl substances in serum by hybrid solid-phase extraction},
  journal = {Environmental Chemistry},
  year = {2018},
  volume = {15},
  number = {2},
  pages = {92--99},
  doi = {10.1071/en17192}
}
Kostenlos starten →