Quantifying total erosion area on vacuum interrupter contacts using an adapted MBDNet
AIP Advances · 01.11.2026 · 16 (11)
DOI: 10.1063/5.0360180 ↗Kurz gefasst
Fachartikel in der Zeitschrift AIP Advances, online erschienen am 09.11.2026. Verfasst von Liting Ma und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province, Department of Education of Liaoning Province.
Abstract (Originalsprache)
Specular reflections, structural slots, and weak damage boundaries complicate image-based measurement of erosion on vacuum interrupter contacts. Methods relying primarily on pixel intensity or chromaticity provide limited spatial context for distinguishing weak erosion boundaries from reflection-induced appearance variations, motivating a calibrated measurement workflow that combines local detail with contextual features. This study develops a workflow that adapts the visual saliency model MBDNet to binary erosion segmentation and physical-area estimation. Contrast enhancement and valid-metal masking are combined with multiscale feature extraction and a weighted segmentation loss. The predicted erosion region is quantified using image-scale calibration. In the preliminary evaluation, the proposed model attained an intersection over union of 0.887 and a relative area error of 4.31% against image annotations. Reference-area comparisons at four interruption counts gave relative differences of 3.40%–4.20%, with predictions exceeding the reference values in all four cases. Square reference specimens with side lengths of 1–10 mm gave a mean area error of ∼1.71%. The distinct results for contact surfaces and reference specimens show why geometric calibration and erosion delineation must be evaluated separately. Total estimated erosion area increased from 16.38 to 145.32 mm2 between the reported 50- and 200-interruption conditions. The workflow provides a basis for laboratory measurement of visible contact-surface damage; broader use requires validation on independent contacts.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Liaoning Province
- Department of Education of Liaoning Province
Zitieren
APA
Ma, L., Sui, G., Chang, M., Wang, T., & Dong, H. (2026). Quantifying total erosion area on vacuum interrupter contacts using an adapted MBDNet. AIP Advances, 16(11). https://doi.org/10.1063/5.0360180
Vancouver
Ma L, Sui G, Chang M, Wang T, Dong H. Quantifying total erosion area on vacuum interrupter contacts using an adapted MBDNet. AIP Advances. 2026;16(11). doi:10.1063/5.0360180
BibTeX
@article{Ma2026,
author = {Ma, Liting and Sui, Guozhu and Chang, Meiyu and Wang, Tianhao and Dong, Huajun},
title = {Quantifying total erosion area on vacuum interrupter contacts using an adapted MBDNet},
journal = {AIP Advances},
year = {2026},
volume = {16},
number = {11},
doi = {10.1063/5.0360180}
}
EUVIMED