EUVIMEDEUVIMED entdecken
Crossref

Upgrades to the National Ignition Facility neutron time-of-flight diagnostic for operation at yields greater than 10 MJ

S Kerr iD, K D Hahn iD, J Jeet iD, M Eckart iD, A S Moore iD, E Mariscal iD, R Hatarik iD, H Khater iD, E Henry iD, D J Schlossberg iD

Review of Scientific Instruments · 01.11.2026 · 97 (11)

DOI: 10.1063/5.0350490 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 06.11.2026. Verfasst von S Kerr und 9 weiteren Autor:innen. Beteiligte Einrichtung: Lawrence Livermore National Laboratory, Livermore, California 94550, USA. Die Arbeit nennt 18 Literaturangaben. Gefördert von: Lawrence Livermore National Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The National Ignition Facility (NIF) is reaching MJ fusion yields and has plans to reach tens of MJ. Diagnostic operation at these yields introduces challenges, from detector linearity at high signal levels to increased backgrounds. We present two upgrades to the NIF neutron time-of-flight (nToF) diagnostic suite that will enable measurements at high yields. First, silver neutron attenuators are being installed in the collimated nToF beamlines, reducing neutron flux and maintaining optimal signal-to-background levels. Silver was selected for its smooth neutron transmission cross section and sufficient γ-ray transmission to retain the gamma peak used for hot-spot velocity measurements. Each line-of-sight will have four insertable silver pucks, providing ∼2–20× attenuation of 14 MeV neutrons. Second, microchannel plate (MCP) photomultiplier tubes using Zener diodes to establish constant MCP-to-anode acceleration voltages have been installed in the quartz Cherenkov detectors. These provide stable instrument response functions across large gain ranges and permit operation at MCP gains near unity. The combined upgrades will allow NIF nToFs to function at all projected future yields.

Autor:innen und Institutionen

  • Lawrence Livermore National Laboratory, Livermore, California 94550, USA.

ORCID-Profile: S Kerr, K D Hahn, J Jeet, M Eckart, A S Moore, E Mariscal, R Hatarik, H Khater, E Henry, D J Schlossberg

Förderung

  • Lawrence Livermore National Laboratory

Zitieren

APA

Kerr, S., Hahn, K. D., Jeet, J., Eckart, M., Moore, A. S., Mariscal, E., Hatarik, R., Khater, H., Henry, E., & Schlossberg, D. J. (2026). Upgrades to the National Ignition Facility neutron time-of-flight diagnostic for operation at yields greater than 10 MJ. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0350490

Vancouver

Kerr S, Hahn KD, Jeet J, Eckart M, Moore AS, Mariscal E, et al. Upgrades to the National Ignition Facility neutron time-of-flight diagnostic for operation at yields greater than 10 MJ. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0350490

BibTeX
@article{Kerr2026,
  author = {Kerr, S and Hahn, K D and Jeet, J and Eckart, M and Moore, A S and Mariscal, E and Hatarik, R and Khater, H and Henry, E and Schlossberg, D J},
  title = {Upgrades to the National Ignition Facility neutron time-of-flight diagnostic for operation at yields greater than 10 MJ},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {11},
  doi = {10.1063/5.0350490}
}
Kostenlos starten →