EUVIMEDEUVIMED entdecken
Crossref

Neutron-induced backgrounds in coaxial cables on the South Pole neutron time-of-flight detector at the National Ignition Facility

S Kerr iD, J Jeet iD, E Mariscal iD, K D Hahn iD, M J Eckart iD, H Khater iD, R M Bionta iD, D Casey iD, J Carrera iD, J Delora-Ellefson iD, E P Hartouni iD, D J Schlossberg iD

Review of Scientific Instruments · 01.12.2024 · 95 (12)

DOI: 10.1063/5.0219568 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 03.12.2024. Verfasst von S Kerr und 11 weiteren Autor:innen. Beteiligte Einrichtung: Lawrence Livermore National Laboratory, Livermore, California 94550, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Lawrence Livermore National Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As neutron yields increase at fusion facilities, a universal symptom the community must deal with is MeV neutron-induced backgrounds in cables running to diagnostics. On the first Gain >1 plasmas in the world, the National Ignition Facility (NIF) neutron time-of-flight (nToF) diagnostic registered significant cable backgrounds that compromised key performance measurements. The South Pole nToF is uniquely located inside the NIF Target Bay shield walls, ∼18 m from the fusion source, and consequently has long coaxial cable runs (>20 m) that see significant neutron fluence. The resulting neutron-driven current in the cable is comparable to the downscattered neutron signal, compromising the downscattered ratio (DSR) measurement. We have characterized this background with a series of on-shot tests and developed a background subtraction technique to mitigate these effects. The background subtracted DSR results are validated against zirconium activation measurements, indicating that we have successfully reclaimed high-quality data output. The ion temperature measurement is found to not be affected by this background. Alternative approaches to addressing neutron-induced cable backgrounds are presented for potential future hardware upgrades.

Autor:innen und Institutionen

  • Lawrence Livermore National Laboratory, Livermore, California 94550, USA.

ORCID-Profile: S Kerr, J Jeet, E Mariscal, K D Hahn, M J Eckart, H Khater, R M Bionta, D Casey, J Carrera, J Delora-Ellefson, E P Hartouni, D J Schlossberg

Förderung

  • Lawrence Livermore National Laboratory

Zitieren

APA

Kerr, S., Jeet, J., Mariscal, E., Hahn, K. D., Eckart, M. J., Khater, H., Bionta, R. M., Casey, D., Carrera, J., Delora-Ellefson, J., Hartouni, E. P., & Schlossberg, D. J. (2024). Neutron-induced backgrounds in coaxial cables on the South Pole neutron time-of-flight detector at the National Ignition Facility. Review of Scientific Instruments, 95(12). https://doi.org/10.1063/5.0219568

Vancouver

Kerr S, Jeet J, Mariscal E, Hahn KD, Eckart MJ, Khater H, et al. Neutron-induced backgrounds in coaxial cables on the South Pole neutron time-of-flight detector at the National Ignition Facility. Review of Scientific Instruments. 2024;95(12). doi:10.1063/5.0219568

BibTeX
@article{Kerr2024,
  author = {Kerr, S and Jeet, J and Mariscal, E and Hahn, K D and Eckart, M J and Khater, H and Bionta, R M and Casey, D and Carrera, J and Delora-Ellefson, J and Hartouni, E P and Schlossberg, D J},
  title = {Neutron-induced backgrounds in coaxial cables on the South Pole neutron time-of-flight detector at the National Ignition Facility},
  journal = {Review of Scientific Instruments},
  year = {2024},
  volume = {95},
  number = {12},
  doi = {10.1063/5.0219568}
}
Kostenlos starten →