EUVIMEDScopri EUVIMED
Crossref

Non-contact human activity recognition system for smart healthcare and elderly care

Haitao Xin, Xiao Cai, Fangzheng Zhu

Review of Scientific Instruments · 2026-11-01 · 97 (11)

DOI: 10.1063/5.0347435 ↗

At a glance

Journal article in Review of Scientific Instruments, published online on 2026-11-23. Written by Haitao Xin and 2 co-authors. 38 references.

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

With the continuous increase in population aging, the demand for long-term health monitoring for elderly people living alone and patients with chronic diseases has been steadily growing. Human activity recognition is regarded as an important supporting technology for smart healthcare and elderly care monitoring. It plays a significant role in fall warning, rehabilitation assessment, and daily activity analysis. Traditional vision-based monitoring methods are limited by privacy concerns, illumination conditions, and occlusion effects. Wearable-device-based methods are affected by low user compliance and a high probability of device omission. To address these issues, a non-contact human activity recognition system based on WiFi Channel State Information (CSI) is proposed in this paper. Variations in multipath propagation caused by human movements are exploited to achieve passive monitoring of human activities. To verify the effectiveness of the proposed method, a CSI activity dataset for healthcare and elderly care scenarios is introduced. The dataset contains six typical human activities from 20 participants under the condition of three receiving antennas and 114 effective subcarriers. Considering that CSI signals simultaneously contain spatial scattering characteristics and temporal dynamic characteristics, a lightweight spatiotemporal asymmetric convolutional neural network is designed. An asymmetric large-kernel convolution structure is adopted to achieve effective decoupling and joint modeling of cross-antenna spatial information and long-term temporal features. As a result, model complexity is reduced while recognition accuracy is maintained. Experimental results show that an activity recognition accuracy of 96.85% is achieved on the dataset. In addition, favorable performance is obtained in terms of model parameter size and inference efficiency. The results indicate that the proposed WiFi CSI-based non-contact activity recognition technology can provide a low-cost, privacy-preserving, and easily deployable solution for hospital wards, elderly care institutions, and home health monitoring.

Cite

APA

Xin, H., Cai, X., & Zhu, F. (2026). Non-contact human activity recognition system for smart healthcare and elderly care. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0347435

Vancouver

Xin H, Cai X, Zhu F. Non-contact human activity recognition system for smart healthcare and elderly care. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0347435

BibTeX
@article{Xin2026,
  author = {Xin, Haitao and Cai, Xiao and Zhu, Fangzheng},
  title = {Non-contact human activity recognition system for smart healthcare and elderly care},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {11},
  doi = {10.1063/5.0347435}
}
Start for free →