EUVIMEDObjevte EUVIMED
Crossref

Three-dimensional effects and turbulence characteristics in heated urban canyons

Chongyu Zhao, Ximeng Kang, Ozgun Ozer, David Topping, Ben Parslew, Shan Zhong

Physics of Fluids · 2026-07-01 · 38 (7)

DOI: 10.1063/5.0342740 ↗

At a glance

Journal article in Physics of Fluids, published online on 2026-07-28. Written by Chongyu Zhao and 5 co-authors. 48 references.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Ground heating in urban environments generates buoyancy that interacts with wind-driven shear and modifies street-canyon ventilation and heat removal. Although thermally affected flows in two-dimensional (2D) canyons have been widely investigated, the response of three-dimensional (3D) canyons remains unclear as lateral exchange, tip-corner eddies, and buoyant uplift occur simultaneously. This study presents a wind tunnel comparison of 2D and 3D street canyons under similar oncoming flow conditions and controlled floor heating, at floor temperatures from ambient to 150 °C for the 2D canyon and to 190 °C for the 3D canyon. Time-resolved and scanning stereo particle image velocimetry and thermocouple measurements quantify mean flow structures, turbulence statistics, turbulent momentum-transfer events, and thermal stratification. Results show that lateral channel flow and tip-corner vortices weaken the mid-span primary recirculation in the 3D canyon compared to the 2D canyon. Ground heating strengthens the buoyancy-assisted updraft along the leeward wall and enhances roof-level exchange. In the 2D canyon, increasing thermal forcing can reorganize the flow toward a more coherent buoyancy-driven regime. In the 3D canyon, lateral exchange persists and maintains stronger spatial variability and event intermittency. Reynolds-stress and quadrant analyses show that moderate thermal forcing amplifies ejection and sweep events near the canyon top, whereas stronger forcing can reduce the intermittency of shear-driven motions in the 2D canyon. Temperature and gradient Richardson number profiles indicate that 3D lateral mixing smoothens local stability gradients while allowing buoyancy-driven vertical heat removal. These findings clarify how three-dimensionality modulates the balance between shear-driven exchange, buoyant uplift, and lateral redistribution in heated urban canyons.

Cite

APA

Zhao, C., Kang, X., Ozer, O., Topping, D., Parslew, B., & Zhong, S. (2026). Three-dimensional effects and turbulence characteristics in heated urban canyons. Physics of Fluids, 38(7). https://doi.org/10.1063/5.0342740

Vancouver

Zhao C, Kang X, Ozer O, Topping D, Parslew B, Zhong S. Three-dimensional effects and turbulence characteristics in heated urban canyons. Physics of Fluids. 2026;38(7). doi:10.1063/5.0342740

BibTeX
@article{Zhao2026,
  author = {Zhao, Chongyu and Kang, Ximeng and Ozer, Ozgun and Topping, David and Parslew, Ben and Zhong, Shan},
  title = {Three-dimensional effects and turbulence characteristics in heated urban canyons},
  journal = {Physics of Fluids},
  year = {2026},
  volume = {38},
  number = {7},
  doi = {10.1063/5.0342740}
}
Start for free →