Pre-stretched wrinkled CuO/laser-induced graphene heterostructures for ultrasensitive strain sensing and bioelectric monitoring
Applied Physics Letters · 02.11.2026 · 129 (18)
DOI: 10.1063/5.0341721 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 03.11.2026. Verfasst von Danlin Li und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangsu Province.
Abstract (Originalsprache)
Concurrently achieving high sensitivity and mechanical resilience remains a central challenge in flexible electronics. This study presents a solution through a highly responsive strain sensor based on hierarchically wrinkled copper oxide/laser-induced graphene heterostructures. An integrated fabrication approach combining in situ precursor doping with a transfer pressure-tailored pre-stretching strategy establishes a directional wrinkled architecture with optimized interfacial bonding, revealing the intrinsic correlations among transfer pressure, microstructure, and sensing performance. This structure resolves the intrinsic trade-off between sensitivity and stretchability, yielding a sensor that exhibits a gauge factor of 12 375, a 60 ms response, and exceptional stability over 7000 cycles. Finite element modeling confirms that the multiscale wrinkled architecture accommodates large deformations through structural unfolding, while density functional theory calculations validate that the CuO decoration optimizes the electronic structure to facilitate rapid interfacial charge transfer. Demonstrated applications underscore its capability to precisely capture diverse biosignals, ranging from large-scale human motion to subtle physiological signals such as radial artery pulses, and to provide high-fidelity electrocardiogram monitoring with performance comparable to that of commercial Ag/AgCl electrodes. This work establishes a promising low-cost, high-performance platform for next-generation wearable healthcare.
Förderung
- Natural Science Foundation of Jiangsu Province
Zitieren
APA
Li, D., Ren, J., Li, F., Feng, Z., Guo, Y., & Zhao, J. (2026). Pre-stretched wrinkled CuO/laser-induced graphene heterostructures for ultrasensitive strain sensing and bioelectric monitoring. Applied Physics Letters, 129(18). https://doi.org/10.1063/5.0341721
Vancouver
Li D, Ren J, Li F, Feng Z, Guo Y, Zhao J. Pre-stretched wrinkled CuO/laser-induced graphene heterostructures for ultrasensitive strain sensing and bioelectric monitoring. Applied Physics Letters. 2026;129(18). doi:10.1063/5.0341721
BibTeX
@article{Li2026,
author = {Li, Danlin and Ren, Jitong and Li, Fangyi and Feng, Zhengdong and Guo, Yanyan and Zhao, Jiang},
title = {Pre-stretched wrinkled CuO/laser-induced graphene heterostructures for ultrasensitive strain sensing and bioelectric monitoring},
journal = {Applied Physics Letters},
year = {2026},
volume = {129},
number = {18},
doi = {10.1063/5.0341721}
}
EUVIMED