EUVIMEDEUVIMED entdecken
Crossref

Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication

Pengju Zhao iD, Lin Zhang iD, Xian Jing iD, Jieqiong Lin iD

Review of Scientific Instruments · 01.08.2026 · 97 (8)

DOI: 10.1063/5.0332592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 06.08.2026. Verfasst von Pengju Zhao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Jilin Provincial Key Laboratory of Micro-Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technolog…. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jilin Provincial Scientific and Technological Development Program, State Key Laboratory of Mechanical System and Vibration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Precision glass molding (PGM) is a near-net-shape process for fabricating high-precision glass optical components, whose replication accuracy depends on coupled thermal, force, displacement, and pressure-holding conditions. To support process-parameter optimization and micro-optical structure replication, an open-architecture, research-oriented molding apparatus was designed, constructed, and evaluated. The compact system integrates short-wave infrared heating, independently regulated upper and lower thermal zones, vacuum/nitrogen atmosphere control, water-cooled seal protection, and force/displacement feedback. Thermal stability tests showed that under a 600 °C holding condition, the deviations of the upper and lower mold-base temperatures from the set temperature eventually converged to within 7 °C, while the two mold bases temperature difference was reduced to within ±1 °C during the stable stage. Both mold bases were maintained above 700 °C for more than 600 s in the ultimate heating test. Mechanically, the apparatus separates chamber actuation from molding loading. A 400 mm electric vertical linear guide opens, closes, and seals the vacuum heating chamber, whereas the lower loading shaft provides a 48 mm loading travel. Micro-displacement control tests showed a minimum return positioning error of 1.226 μm over a 200 μm total travel. Force feedback is provided by an external 5 kN pressure sensor with 0.05% full-scale accuracy, while the actual force-tracking behavior was shown to depend on target force and pressure-holding regulation speed rather than on a single universal control-accuracy value. Finally, an As2Se3 chalcogenide glass molding experiment was conducted, confirming that the apparatus can serve as an open research-oriented platform for PGM process studies.

Autor:innen und Institutionen

  • Jilin Provincial Key Laboratory of Micro-Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Yan'an Ave. 2055, Changchun, Jilin 130012, People's Republic of Chi…
  • Jilin Provincial Key Laboratory of International Science and Technology Cooperation for High Performance Manufacturing and Testing, School of Mechatronic Engineering, Changchun University of Technology, Yan'an Ave. 2055…

ORCID-Profile: Pengju Zhao, Lin Zhang, Xian Jing, Jieqiong Lin

Förderung

  • National Natural Science Foundation of China
  • Jilin Provincial Scientific and Technological Development Program
  • State Key Laboratory of Mechanical System and Vibration

Zitieren

APA

Zhao, P., Zhang, L., Jing, X., & Lin, J. (2026). Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication. Review of Scientific Instruments, 97(8). https://doi.org/10.1063/5.0332592

Vancouver

Zhao P, Zhang L, Jing X, Lin J. Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication. Review of Scientific Instruments. 2026;97(8). doi:10.1063/5.0332592

BibTeX
@article{Zhao2026,
  author = {Zhao, Pengju and Zhang, Lin and Jing, Xian and Lin, Jieqiong},
  title = {Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {8},
  doi = {10.1063/5.0332592}
}
Kostenlos starten →