Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication
Review of Scientific Instruments · 01.08.2026 · 97 (8)
DOI: 10.1063/5.0332592 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 06.08.2026. Verfasst von Pengju Zhao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Jilin Provincial Key Laboratory of Micro-Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technolog…. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jilin Provincial Scientific and Technological Development Program, State Key Laboratory of Mechanical System and Vibration.
Abstract (Originalsprache)
Precision glass molding (PGM) is a near-net-shape process for fabricating high-precision glass optical components, whose replication accuracy depends on coupled thermal, force, displacement, and pressure-holding conditions. To support process-parameter optimization and micro-optical structure replication, an open-architecture, research-oriented molding apparatus was designed, constructed, and evaluated. The compact system integrates short-wave infrared heating, independently regulated upper and lower thermal zones, vacuum/nitrogen atmosphere control, water-cooled seal protection, and force/displacement feedback. Thermal stability tests showed that under a 600 °C holding condition, the deviations of the upper and lower mold-base temperatures from the set temperature eventually converged to within 7 °C, while the two mold bases temperature difference was reduced to within ±1 °C during the stable stage. Both mold bases were maintained above 700 °C for more than 600 s in the ultimate heating test. Mechanically, the apparatus separates chamber actuation from molding loading. A 400 mm electric vertical linear guide opens, closes, and seals the vacuum heating chamber, whereas the lower loading shaft provides a 48 mm loading travel. Micro-displacement control tests showed a minimum return positioning error of 1.226 μm over a 200 μm total travel. Force feedback is provided by an external 5 kN pressure sensor with 0.05% full-scale accuracy, while the actual force-tracking behavior was shown to depend on target force and pressure-holding regulation speed rather than on a single universal control-accuracy value. Finally, an As2Se3 chalcogenide glass molding experiment was conducted, confirming that the apparatus can serve as an open research-oriented platform for PGM process studies.
Autor:innen und Institutionen
- Jilin Provincial Key Laboratory of Micro-Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Yan'an Ave. 2055, Changchun, Jilin 130012, People's Republic of Chi…
- Jilin Provincial Key Laboratory of International Science and Technology Cooperation for High Performance Manufacturing and Testing, School of Mechatronic Engineering, Changchun University of Technology, Yan'an Ave. 2055…
ORCID-Profile: Pengju Zhao, Lin Zhang, Xian Jing, Jieqiong Lin
Förderung
- National Natural Science Foundation of China
- Jilin Provincial Scientific and Technological Development Program
- State Key Laboratory of Mechanical System and Vibration
Zitieren
APA
Zhao, P., Zhang, L., Jing, X., & Lin, J. (2026). Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication. Review of Scientific Instruments, 97(8). https://doi.org/10.1063/5.0332592
Vancouver
Zhao P, Zhang L, Jing X, Lin J. Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication. Review of Scientific Instruments. 2026;97(8). doi:10.1063/5.0332592
BibTeX
@article{Zhao2026,
author = {Zhao, Pengju and Zhang, Lin and Jing, Xian and Lin, Jieqiong},
title = {Development and experimental evaluation of a research-oriented precision glass molding apparatus for micro-optical structure replication},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {8},
doi = {10.1063/5.0332592}
}
EUVIMED