Imaging of two-dimensional ion-beam profiles using a scanning Faraday cup array combined with a 128-channel picoammeter system

Xiaoxun Song, Junliang Liu iD, Deyang Yu iD, Tao Guo, Lidong Ma, Xin Li, Cheng Qian iD, Xing Fang, Yucheng Feng, Wenhui Zhang, Yuhan Zhai iD, Hongyi Ma

Review of Scientific Instruments · 01.06.2026 · 97 (6)

DOI: 10.1063/5.0327019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 18.06.2026. Verfasst von Xiaoxun Song und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000, China. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A two-dimensional beam-profile monitor has been constructed based on a scanning Faraday cup array, a 128-channel picoammeter system, and a LabVIEW-based data acquisition system. The Faraday cup array consists of 128 small Faraday cups, while each is connected to an independent picoammeter of the picoammeter system. It is driven across the ion beam by a servo motor and images the two-dimensional beam profile by directly measuring the absolute electric current distribution. The benefit from the avoidance of readout switching between different Faraday cups is that the crosstalk is negligible during a beam scanning. Typically, this monitor scans a beam cross section of 76.8 × 76.8 mm2 within 18–420 seconds. Tests with 50-keV O5+ and 1.8-MeV Xe25+ beams show that an ion beam with beam flux greater than ∼1 pA/mm2 can be clearly distinguished and a spatial resolution of ∼0.6 mm can be achieved. The total beam current measured by this device was calibrated using a Faraday cup, showing a systematic negative deviation of ∼6%–8% relative to the reference current, which is mainly attributed to inlet diameter tolerance and alignment errors.

Autor:innen und Institutionen

  • Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000, China.
  • School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000, China.
  • University of Chinese Academy of Sciences, Beijing 100049, China.
  • Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516000, China.

ORCID-Profile: Junliang Liu, Deyang Yu, Cheng Qian, Yuhan Zhai

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Song, X., Liu, J., Yu, D., Guo, T., Ma, L., Li, X., Qian, C., Fang, X., Feng, Y., Zhang, W., Zhai, Y., & Ma, H. (2026). Imaging of two-dimensional ion-beam profiles using a scanning Faraday cup array combined with a 128-channel picoammeter system. Review of Scientific Instruments, 97(6). https://doi.org/10.1063/5.0327019

Vancouver

Song X, Liu J, Yu D, Guo T, Ma L, Li X, et al. Imaging of two-dimensional ion-beam profiles using a scanning Faraday cup array combined with a 128-channel picoammeter system. Review of Scientific Instruments. 2026;97(6). doi:10.1063/5.0327019

BibTeX
@article{Song2026,
  author = {Song, Xiaoxun and Liu, Junliang and Yu, Deyang and Guo, Tao and Ma, Lidong and Li, Xin and Qian, Cheng and Fang, Xing and Feng, Yucheng and Zhang, Wenhui and Zhai, Yuhan and Ma, Hongyi},
  title = {Imaging of two-dimensional ion-beam profiles using a scanning Faraday cup array combined with a 128-channel picoammeter system},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {6},
  doi = {10.1063/5.0327019}
}
Kostenlos starten →