EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A 128‐channel receive array for cortical brain imaging at 7 T

Bernhard Gruber iD, Jason P Stockmann iD, Azma Mareyam iD, Boris Keil iD, Berkin Bilgic iD, Yulin Chang, Ehsan Kazemivalipour iD, Alexander J S Beckett iD, An T Vu iD, David A Feinberg, Lawrence L Wald iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29798 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Bernhard Gruber und 10 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, Ma…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A 128‐channel receive‐only array for brain imaging at 7 T was simulated, designed, constructed, and tested within a high‐performance head gradient designed for high‐resolution functional imaging.

Methods

The coil used a tight‐fitting helmet geometry populated with 128 loop elements and preamplifiers to fit into a 39 cm diameter space inside a built‐in gradient. The signal‐to‐noise ratio (SNR) and parallel imaging performance (1/ g ) were measured in vivo and simulated using electromagnetic modeling. The histogram of 1/ g factors was analyzed to assess the range of performance. The array's performance was compared to the industry‐standard 32‐channel receive array and a 64‐channel research array.

Results

It was possible to construct the 128‐channel array with body noise–dominated loops producing an average noise correlation of 5.4%. Measurements showed increased sensitivity compared with the 32‐channel and 64‐channel array through a combination of higher intrinsic SNR and g‐factor improvements. For unaccelerated imaging, the 128‐channel array showed SNR gains of 17.6% and 9.3% compared to the 32‐channel and 64‐channel array, respectively, at the center of the brain and 42% and 18% higher SNR in the peripheral brain regions including the cortex. For R = 5 accelerated imaging, these gains were 44.2% and 24.3% at the brain center and 86.7% and 48.7% in the cortex. The 1/ g ‐factor histograms show both an improved mean and a tighter distribution by increasing the channel count, with both effects becoming more pronounced at higher accelerations.

Conclusion

The experimental results confirm that increasing the channel count to 128 channels is beneficial for 7T brain imaging, both for increasing SNR in peripheral brain regions and for accelerated imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainSignal-To-Noise RatioPhantoms, ImagingNeuroimagingEquipment Design

Stichwörter der Autor:innen

cortical imaginghigh-field MR phased array coilsneuroimagingparallel imagingreceive coilssignal to noise ratio

Autor:innen und Institutionen

  • Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts, USA.
  • High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University, Vienna, Austria.
  • Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, Mittelhessen University of Applied Sciences, Giessen, Germany.
  • Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps University of Marburg, Marburg, Germany.
  • Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA.
  • Advanced MRI Technologies, Sebastopol, California, USA.

ORCID-Profile: Bernhard Gruber, Jason P Stockmann, Azma Mareyam, Boris Keil, Berkin Bilgic, Ehsan Kazemivalipour, Alexander J S Beckett, An T Vu, Lawrence L Wald

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Gruber, B., Stockmann, J. P., Mareyam, A., Keil, B., Bilgic, B., Chang, Y., Kazemivalipour, E., Beckett, A. J. S., Vu, A. T., Feinberg, D. A., & Wald, L. L. (2023). A 128‐channel receive array for cortical brain imaging at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29798

Vancouver

Gruber B, Stockmann JP, Mareyam A, Keil B, Bilgic B, Chang Y, et al. A 128‐channel receive array for cortical brain imaging at 7 T. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29798

BibTeX
@article{Gruber2023,
  author = {Gruber, Bernhard and Stockmann, Jason P and Mareyam, Azma and Keil, Boris and Bilgic, Berkin and Chang, Yulin and Kazemivalipour, Ehsan and Beckett, Alexander J S and Vu, An T and Feinberg, David A and Wald, Lawrence L},
  title = {A 128‐channel receive array for cortical brain imaging at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29798}
}
Kostenlos starten →