A 40 GSample/s (GSPS), 13 GHz bandwidth time-interleaved analog-to-digital converter (TIADC) system with comprehensive calibration for mismatches and frequency response distortion
Review of Scientific Instruments · 01.06.2026 · 97 (6)
DOI: 10.1063/5.0317625 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 08.06.2026. Verfasst von Benny Siu Lam Hung und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shenzhen Institute for Advanced Study, UESTC Shenzhen Institute for Advanced Study, UESTC, ShenZhen, China. Die Arbeit nennt 18 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province.
Abstract (Originalsprache)
Data acquisition systems based on the time-interleaved analog-to-digital converter (TIADC) parallel sampling architecture offer an effective solution to overcome the performance limitations of single-chip analog-to-digital converters (ADCs), addressing the growing demand for signal bandwidth multiplication in applications such as wideband receivers and high-end electronic test instruments. However, mismatches in sampling time, gain, and offset among sub-ADCs within the TIADC system, coupled with frequency response distortion, i.e., amplitude frequency distortion (AFD) and phase frequency distortion (PFD), in the analog front end, pose significant challenges to system performance. These non-idealities adversely affect both dynamic performance and signal reconstruction accuracy. This paper presents a statistics-based estimation algorithm for TIADC mismatch errors and designs a digital finite impulse response filter capable of arbitrary frequency response to jointly compensate AFD and PFD. The proposed method is validated on a hardware system operating at 40 GSample/s with a 13 GHz bandwidth. Experimental results demonstrate a 15 dB improvement in system signal-to-noise ratio (SNR), a post-compensation amplitude frequency response fluctuation of 0.98 dB, and an enhanced rise time of 38.51 ps for the step signal with a 13 GHz bandwidth.
Autor:innen und Institutionen
- Shenzhen Institute for Advanced Study, UESTC Shenzhen Institute for Advanced Study, UESTC, ShenZhen, China.
- University of Electronic Science and Technology of China University of Electronic Science and Technology of China, Chengdu, China.
ORCID-Profile: Benny Siu Lam Hung, Peng Ye, Jie Meng, Kuojun Yang
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Sichuan Province
Zitieren
APA
Hung, B. S. L., Ye, P., Meng, J., & Yang, K. (2026). A 40 GSample/s (GSPS), 13 GHz bandwidth time-interleaved analog-to-digital converter (TIADC) system with comprehensive calibration for mismatches and frequency response distortion. Review of Scientific Instruments, 97(6). https://doi.org/10.1063/5.0317625
Vancouver
Hung BSL, Ye P, Meng J, Yang K. A 40 GSample/s (GSPS), 13 GHz bandwidth time-interleaved analog-to-digital converter (TIADC) system with comprehensive calibration for mismatches and frequency response distortion. Review of Scientific Instruments. 2026;97(6). doi:10.1063/5.0317625
BibTeX
@article{Hung2026,
author = {Hung, Benny Siu Lam and Ye, Peng and Meng, Jie and Yang, Kuojun},
title = {A 40 GSample/s (GSPS), 13 GHz bandwidth time-interleaved analog-to-digital converter (TIADC) system with comprehensive calibration for mismatches and frequency response distortion},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {6},
doi = {10.1063/5.0317625}
}
EUVIMED