A frequency response mismatches estimation method for time interleaved analog-to-digital converter based on chirp-Z transform
Review of Scientific Instruments · 01.04.2026 · 97 (4)
DOI: 10.1063/5.0316379 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 06.04.2026. Verfasst von Sitao Mei und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
This article proposes a novel frequency-response mismatch estimation method for time-interleaved analog-to-digital converters (TIADCs) based on the Chirp-Z Transform (CZT). Unlike the traditional Fast Fourier Transform (FFT)-based estimation, which suffers from fixed frequency resolution and spectral leakage, the CZT offers flexible frequency mapping with adjustable start frequency, bandwidth, and resolution. This flexibility enables high-precision spectral analysis at arbitrary frequency points, significantly improving the accuracy and stability of amplitude and phase mismatch estimation, particularly near sub-ADC Nyquist boundaries. Both simulation and hardware experiments validate the proposed approach. Therefore, the CZT can avoid spectral leakage by flexibly adjusting its computation parameters. Simulation results demonstrate that the CZT-based estimation reduces spectral leakage and improves calibration accuracy by ∼7 dB compared with the FFT-based method in spurious-free dynamic range (SFDR). Furthermore, a 4-channel 12.5 GS/s TIADC prototype is used to verify the feasibility of the proposed algorithm, showing a 20 dB enhancement in SFDR after calibration. The results confirm that the proposed CZT-based estimation provides a high-resolution, leakage-free, and computationally efficient solution for precise channel mismatch calibration in broadband TIADC systems.
Autor:innen und Institutionen
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Chengdu 611731, China.
ORCID-Profile: Sitao Mei, Yusen Wang, Yijiu Zhao
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Sichuan Province
- China Postdoctoral Science Foundation
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Mei, S., Zhao, Y., Wang, Y., Zhao, Y., & Wang, H. (2026). A frequency response mismatches estimation method for time interleaved analog-to-digital converter based on chirp-Z transform. Review of Scientific Instruments, 97(4). https://doi.org/10.1063/5.0316379
Vancouver
Mei S, Zhao Y, Wang Y, Zhao Y, Wang H. A frequency response mismatches estimation method for time interleaved analog-to-digital converter based on chirp-Z transform. Review of Scientific Instruments. 2026;97(4). doi:10.1063/5.0316379
BibTeX
@article{Mei2026,
author = {Mei, Sitao and Zhao, Yafeng and Wang, Yusen and Zhao, Yijiu and Wang, Houjun},
title = {A frequency response mismatches estimation method for time interleaved analog-to-digital converter based on chirp-Z transform},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {4},
doi = {10.1063/5.0316379}
}
EUVIMED