Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 18.03.2026. Verfasst von Feng Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Plasma Physics, Laser Fusion Research Center (LFRC), China Academy of Engineering Physics (CAEP), Mianyang 621900, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Science Challenge Project, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compton photography is a crucial diagnostic technique that utilizes picosecond ultra-short pulse lasers to generate hard x rays (50–200 keV) for backlighting inertial confinement fusion capsules at stagnation time, providing fuel density distribution measurements. To enhance the signal-to-noise ratio of backlighting under limited picosecond laser energy conditions, an online hard x-ray detector with high detection efficiency and gating capability is required to mitigate interference from long-duration x-ray pulses. To address this, we developed a dual microchannel plate (MCP) gated image intensifier system. MCP devices with varying specifications, containing 37% and 51% lead by weight, were fabricated and integrated into image intensifiers for detective quantum efficiency testing. The results showed that the dual MCP image intensifier with 37% lead achieved a maximum detective quantum efficiency of ∼4.48%, comparable to that of the AXIS system at the National Ignition Facility as reported in literature. Furthermore, the dual MCP image intensifier with 51% lead demonstrated a significantly higher quantum detection efficiency of 7.15%. Experiments conducted at the ShenGuang-II upgraded facility tested the spatial resolution and gating functionality of the dual MCP gated image intensifier, revealing a spatial resolution of 2.09 lp/mm and effective suppression of nanosecond-long x-ray interference.

Autor:innen und Institutionen

  • National Key Laboratory of Plasma Physics, Laser Fusion Research Center (LFRC), China Academy of Engineering Physics (CAEP), Mianyang 621900, China.
  • National Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
  • Shanghai Institute of Laser Plasma, China Academy of Engineering Physics (CAEP), Shanghai 201800, China.

ORCID-Profile: Feng Zhang, Lianqiang Shan, Penghui Feng, Yongsheng Gou, Zhongjin Chen, Weimin Zhou, Yuqiu Gu

Förderung

  • Science Challenge Project
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, F., Shan, L., Feng, P., Yu, M., Yuan, Z., Tian, C., Yang, L., Gou, Y., Chen, Z., Zhou, W., & Gu, Y. (2026). Dual MCP gated image intensifier for online high-energy x-ray detection. Review of Scientific Instruments, 97(3). https://doi.org/10.1063/5.0316735

Vancouver

Zhang F, Shan L, Feng P, Yu M, Yuan Z, Tian C, et al. Dual MCP gated image intensifier for online high-energy x-ray detection. Review of Scientific Instruments. 2026;97(3). doi:10.1063/5.0316735

BibTeX
@article{Zhang2026,
  author = {Zhang, Feng and Shan, Lianqiang and Feng, Penghui and Yu, Minghai and Yuan, Zongqiang and Tian, Chao and Yang, Lei and Gou, Yongsheng and Chen, Zhongjin and Zhou, Weimin and Gu, Yuqiu},
  title = {Dual MCP gated image intensifier for online high-energy x-ray detection},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {3},
  doi = {10.1063/5.0316735}
}
Kostenlos starten →