A Reflectance–based multimodal wearable photoplethysmography (PPG) sensor
Review of Scientific Instruments · 2026
DOI: 10.1063/5.0304023 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, 2026. Verfasst von Ravi Durbha und 1 weiteren Autor:innen. Beteiligte Einrichtung: AICS Lab, Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, USA. Hauptthemen laut MEDLINE: Photoplethysmography, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Science Foundation.
Abstract (Originalsprache)
This paper presents ChromaSense, a reflectance-based wearable photoplethysmography (PPG) sensor designed for robust monitoring of vital signs, including blood oxygen saturation (SpO2), pulse rate, and respiration rate across diverse skin tones. Conventional PPG-based sensors are susceptible to melanin-induced optical attenuation, which can contribute to measurement error, particularly in individuals with darker skin pigmentation. To address this limitation, ChromaSense integrates spectral colorimetric sensing to estimate skin reflectance and adaptively adjust LED drive current. The system was evaluated on a cohort of 50 participants spanning the Fitzpatrick skin tone scale. For SpO2, the device achieved a root-mean-square accuracy of 1.36% relative to a Food and Drug Administration-cleared reference pulse oximeter (Masimo MightySAT), satisfying the ISO 80601-2-61:2013 standard requirement of ≤3.5%. Bland–Altman analysis showed a mean bias of −0.27% with 95% limits of agreement from −2.91% to 2.36%. For pulse rate estimation, 84% of measurements were within ±10% of the reference values, and for respiration rate estimation, 90% of measurements were within ±5 breaths per minute of the reference values. A one-way analysis of variance (ANOVA) showed no statistically significant differences in SpO2 measurement error across Fitzpatrick skin types (p = 0.518). These results suggest that the proposed multimodal sensing strategy mitigates skin-tone-dependent variability within the evaluated cohort and enables consistent physiological measurement performance across diverse users.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- AICS Lab, Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, USA.
- Department of Computer Science, Tufts University, Medford, Massachusetts 02155, USA.
ORCID-Profile: Ravi Durbha, Valencia Koomson
Förderung
- National Science Foundation
Zitieren
APA
Durbha, R., & Koomson, V. (2026). A Reflectance–based multimodal wearable photoplethysmography (PPG) sensor. Review of Scientific Instruments. https://doi.org/10.1063/5.0304023
Vancouver
Durbha R, Koomson V. A Reflectance–based multimodal wearable photoplethysmography (PPG) sensor. Review of Scientific Instruments. 2026. doi:10.1063/5.0304023
BibTeX
@article{Durbha2026,
author = {Durbha, Ravi and Koomson, Valencia},
title = {A Reflectance–based multimodal wearable photoplethysmography (PPG) sensor},
journal = {Review of Scientific Instruments},
year = {2026},
doi = {10.1063/5.0304023}
}
EUVIMED