Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data

D M Beltukova iD, V P Belik iD, O V Smirnov iD, I V Semenova iD, O S Vasyutinskii iD

Review of Scientific Instruments · 01.04.2026 · 97 (4)

DOI: 10.1063/5.0300693 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.04.2026. Verfasst von D M Beltukova und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ioffe Institute, Russian Academy of Sciences, 26, Polytekhnicheskaya, St.Petersburg 194021, Russia. Die Arbeit nennt 44 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, we considered the autoluminescence of three IR bandpass dichroic filters, occurring in their transmission bands under excitation in visible, as a potential source of erroneous interpretation of experimental results. An interference filter with the transmission band centered at 1270 nm, used for the detection of singlet oxygen phosphorescence, and two other IR filters with the transmission bands centered at 1064 and 1047 nm were under study. All three filters were shown to emit noticeable luminescence within their transmission bands under excitation at 405, 440, 510, and 660 nm. The determined luminescence decay times varied from 0.1 to >20 μs and depended on the excitation wavelength. The results obtained suggest that this potential parasitic luminescence should be carefully taken into account in experiments with low-intensity luminescence signals because its underestimation can corrupt the interpretation of the experimental data.

Autor:innen und Institutionen

  • Ioffe Institute, Russian Academy of Sciences, 26, Polytekhnicheskaya, St.Petersburg 194021, Russia.

ORCID-Profile: D M Beltukova, V P Belik, O V Smirnov, I V Semenova, O S Vasyutinskii

Zitieren

APA

Beltukova, D. M., Belik, V. P., Smirnov, O. V., Semenova, I. V., & Vasyutinskii, O. S. (2026). Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data. Review of Scientific Instruments, 97(4). https://doi.org/10.1063/5.0300693

Vancouver

Beltukova DM, Belik VP, Smirnov OV, Semenova IV, Vasyutinskii OS. Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data. Review of Scientific Instruments. 2026;97(4). doi:10.1063/5.0300693

BibTeX
@article{Beltukova2026,
  author = {Beltukova, D M and Belik, V P and Smirnov, O V and Semenova, I V and Vasyutinskii, O S},
  title = {Luminescence of bandpass dichroic filters within their transmission band can result in misinterpretation of experimental data},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {4},
  doi = {10.1063/5.0300693}
}
Kostenlos starten →