Quantifying the effects of neutron fluence on proton signal retention in CR-39
Review of Scientific Instruments · 01.10.2024 · 95 (10)
DOI: 10.1063/5.0219479 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 02.10.2024. Verfasst von L Russell und 17 weiteren Autor:innen. Beteiligte Einrichtung: Massachusetts Institute of Technology, Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Nuclear Security Administration, Lawrence Livermore National Laboratory.
Abstract (Originalsprache)
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
Autor:innen und Institutionen
- Massachusetts Institute of Technology, Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA.
ORCID-Profile: L Russell, T M Johnson, Y Lawrence, B Reichelt, N Vanderloo, M Cufari, B I Buschmann, S Dannhoff, A DeVault, T Evans, B C Foo, J H Kunimune, J A Pearcy, J Vargas, M Gatu Johnson, J Frenje
Förderung
- National Nuclear Security Administration
- Lawrence Livermore National Laboratory
Zitieren
APA
Russell, L., Johnson, T. M., Lawrence, Y., Reichelt, B., Vanderloo, N., Cufari, M., Buschmann, B. I., Dannhoff, S., DeVault, A., Doeg, E., Evans, T., Foo, B. C., Frankel, R., Kunimune, J. H., Pearcy, J. A., Vargas, J., Gatu Johnson, M., & Frenje, J. (2024). Quantifying the effects of neutron fluence on proton signal retention in CR-39. Review of Scientific Instruments, 95(10). https://doi.org/10.1063/5.0219479
Vancouver
Russell L, Johnson TM, Lawrence Y, Reichelt B, Vanderloo N, Cufari M, et al. Quantifying the effects of neutron fluence on proton signal retention in CR-39. Review of Scientific Instruments. 2024;95(10). doi:10.1063/5.0219479
BibTeX
@article{Russell2024,
author = {Russell, L and Johnson, T M and Lawrence, Y and Reichelt, B and Vanderloo, N and Cufari, M and Buschmann, B I and Dannhoff, S and DeVault, A and Doeg, E and Evans, T and Foo, B C and Frankel, R and Kunimune, J H and Pearcy, J A and Vargas, J and Gatu Johnson, M and Frenje, J},
title = {Quantifying the effects of neutron fluence on proton signal retention in CR-39},
journal = {Review of Scientific Instruments},
year = {2024},
volume = {95},
number = {10},
doi = {10.1063/5.0219479}
}
EUVIMED