Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 11.09.2024. Verfasst von J A Reusch und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Engineering and Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dVcm/dt ∼ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the Bp coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

Autor:innen und Institutionen

  • Department of Nuclear Engineering and Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA.

ORCID-Profile: J A Reusch, M W Aslin, M W Bongard, S J Diem, J A Goetz, M D Nornberg, A S Rajendra, S Redd, C Rodriguez Sanchez, R K Sassella, A C Sontag, J D Weberski, G R Winz

Förderung

  • U.S. Department of Energy

Zitieren

APA

Reusch, J. A., Aslin, M. W., Bongard, M. W., Diem, S. J., Goetz, J. A., Nornberg, M. D., Rajendra, A. S., Redd, S., Rodriguez Sanchez, C., Sassella, R. K., Sontag, A. C., Weberski, J. D., & Winz, G. R. (2024). A magnetic diagnostic suite for the Pegasus-III experiment. Review of Scientific Instruments, 95(9). https://doi.org/10.1063/5.0219341

Vancouver

Reusch JA, Aslin MW, Bongard MW, Diem SJ, Goetz JA, Nornberg MD, et al. A magnetic diagnostic suite for the Pegasus-III experiment. Review of Scientific Instruments. 2024;95(9). doi:10.1063/5.0219341

BibTeX
@article{Reusch2024,
  author = {Reusch, J A and Aslin, M W and Bongard, M W and Diem, S J and Goetz, J A and Nornberg, M D and Rajendra, A S and Redd, S and Rodriguez Sanchez, C and Sassella, R K and Sontag, A C and Weberski, J D and Winz, G R},
  title = {A magnetic diagnostic suite for the Pegasus-III experiment},
  journal = {Review of Scientific Instruments},
  year = {2024},
  volume = {95},
  number = {9},
  doi = {10.1063/5.0219341}
}
Kostenlos starten →