Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay
Langmuir · 09.12.2025 · 41 (48) · 32432-32442
DOI: 10.1021/acs.langmuir.5c04175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 25.11.2025. Verfasst von Gabriel Tai Huynh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Macromolecules and Biomaterials, National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan. Hauptthemen laut MEDLINE: Methacrylates, Polyethylene Glycols, Polymers. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Nonspecific protein absorption is an ongoing problem in the development of highly sensitive magnetic particle (MP)-based diagnostic assays, whereby the MP surface undergoes biofouling, significantly reducing the limit of detection and sensitivity of the device. In this study, a bioinert, concentrated polymer brush (CPB) composed of poly[poly(ethylene oxide) methyl ether methacrylate] (PPEGMA) was employed to reduce the absorption of protein onto the MP surfaces; and an anti-human serum albumin antibody (Ab) was then immobilized onto the brush layer by click chemistry to demonstrate its application as an immunoassay platform. The amount of antibody grafted onto the ends of the brush coating was quantified by a BCA assay with a high grafting efficiency (∼0.80 antibody per chain). Furthermore, when using the antibody-conjugated CPB-coated MPs (MP-PPEGMA-Ab) as an immunoassay platform, we were able to determine the capture efficacy of human serum albumin (HSA) in both a buffered solution and diluted human serum by colorimetric analysis, and further confirmation was achieved via liquid chromatography/mass spectrometry, in which our MPs showed a high selectivity toward the targeted analyte. Lastly, we demonstrated that MP-PPEGMA-Ab was capable of detecting human serum albumin at a concentration as low as 6.4 ng mL-1, 30% more sensitive than the unmodified MP, demonstrating the impact of CPBs on diagnostic assays. Due to their high selectivity and sensitivity, our CPB-based MPs are expected to be applicable for a wide range of immunoassay applications by employing different bioinert polymers and biofunctional groups.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research Center for Macromolecules and Biomaterials, National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan.
- DSM Ahead/TS, 6167 DR Geleen, The Netherlands.
- Graduate School of Life Science, Hokkaido University, Kita 10, Nishi 8, Sapporo 060-0808, Japan.
ORCID-Profile: Tomohiko Yamazaki, Chiaki Yoshikawa
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Huynh, G. T., Qiu, J., van den Bosch, E., Yamazaki, T., & Yoshikawa, C. (2025). Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay. Langmuir, 41(48), 32432-32442. https://doi.org/10.1021/acs.langmuir.5c04175
Vancouver
Huynh GT, Qiu J, van den Bosch E, Yamazaki T, Yoshikawa C. Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay. Langmuir. 2025;41(48):32432-32442. doi:10.1021/acs.langmuir.5c04175
BibTeX
@article{Huynh2025,
author = {Huynh, Gabriel Tai and Qiu, Jun and van den Bosch, Edith and Yamazaki, Tomohiko and Yoshikawa, Chiaki},
title = {Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay},
journal = {Langmuir},
year = {2025},
volume = {41},
number = {48},
pages = {32432--32442},
doi = {10.1021/acs.langmuir.5c04175}
}
EUVIMED