EUVIMEDEUVIMED entdecken
Crossref

A correction method for radial distortion and nonlinear response of infrared cameras

Shuangbao Shu iD, Yufeng Fu, Shenglin Liu, Yuzhong Zhang iD, Tengda Zhang iD, Tianqi Wu iD, Xinyu Gao

Review of Scientific Instruments · 01.03.2024 · 95 (3)

DOI: 10.1063/5.0187807 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.03.2024. Verfasst von Shuangbao Shu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Opto-electronics Engineering, Hefei Univ…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Central University Basic Research Fund of China, National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The key feature of non-contact temperature measurement provided by infrared (IR) cameras underpins their versatility. However, the accuracy of temperature measurements with IR cameras depends on imaging quality due to their non-contact nature, such as the lens, body temperature, and measurement environment. This paper addresses the correction of radial distortion and nonlinear response issues in IR cameras. To address radial distortion, we have designed a passive checkerboard calibration board specifically for infrared cameras. This board is used to calibrate the IR camera and derive the necessary camera parameters. Subsequently, these parameters are applied during the actual measurement process to rectify radial distortion effectively. Building on the radial distortion correction method mentioned above, we propose a multi-point segmented calibration approach that considers different temperature ranges and imaging regions. This method alleviates the issue of reduced temperature measurement accuracy due to variations in camera responses by computing gain and offset coefficient matrices for each temperature range. Experimental results demonstrate the effectiveness of the calibration board in correcting radial distortion in IR cameras, with a mean reprojection error of less than 0.16 pixels. Regarding the nonlinear response problem, the introduced method significantly reduces the relative error in temperature measurement. In the verification phase, spanning from 100 to 500 °C, the average relative error in temperature measurement decreases by 0.49% from 1.61% before and after correction, which highlights a substantial improvement in temperature measurement accuracy. This work gives a useful reference to improve the imaging quality and temperature measurement accuracy using infrared cameras.

Autor:innen und Institutionen

  • Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei 230009, China.

ORCID-Profile: Shuangbao Shu, Yuzhong Zhang, Tengda Zhang, Tianqi Wu

Förderung

  • Central University Basic Research Fund of China
  • National Key Research and Development Program of China

Zitieren

APA

Shu, S., Fu, Y., Liu, S., Zhang, Y., Zhang, T., Wu, T., & Gao, X. (2024). A correction method for radial distortion and nonlinear response of infrared cameras. Review of Scientific Instruments, 95(3). https://doi.org/10.1063/5.0187807

Vancouver

Shu S, Fu Y, Liu S, Zhang Y, Zhang T, Wu T, et al. A correction method for radial distortion and nonlinear response of infrared cameras. Review of Scientific Instruments. 2024;95(3). doi:10.1063/5.0187807

BibTeX
@article{Shu2024,
  author = {Shu, Shuangbao and Fu, Yufeng and Liu, Shenglin and Zhang, Yuzhong and Zhang, Tengda and Wu, Tianqi and Gao, Xinyu},
  title = {A correction method for radial distortion and nonlinear response of infrared cameras},
  journal = {Review of Scientific Instruments},
  year = {2024},
  volume = {95},
  number = {3},
  doi = {10.1063/5.0187807}
}
Kostenlos starten →