The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes
Review of Scientific Instruments · 01.02.2024 · 95 (2)
DOI: 10.1063/5.0178066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 22.02.2024. Verfasst von K Yamada und 26 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Graduate School of Science, The University of Tokyo, Tokyo 113-0033, Japan. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 97 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, High Energy Physics, Simons Foundation.
Abstract (Originalsprache)
We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (⌀0.42 m) and large (⌀6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ∼50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad s. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.
Autor:innen und Institutionen
- Department of Physics, Graduate School of Science, The University of Tokyo, Tokyo 113-0033, Japan.
- Department of Physics, University of California, San Diego, La Jolla, California 92093, USA.
- Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan.
- Kavli Institute for the Physics and Mathematics of the Universe (WPI), UTIAS, The University of Tokyo, Chiba 277-8583, Japan.
- Physics Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
- Department of Physics, University of California, Berkeley, California 94720, USA.
ORCID-Profile: K Yamada, B Bixler, Y Sakurai, P C Ashton, J Sugiyama, K Arnold, J Begin, L Corbett, S Day-Weiss, N Galitzki, C A Hill, B R Johnson, B Jost, A Kusaka, B J Koopman, J Lashner, A T Lee, A Mangu, H Nishino, L A Page, M J Randall, D Sasaki, X Song, J Spisak, T Tsan, Y Wang, P A Williams
Förderung
- Japan Society for the Promotion of Science
- High Energy Physics
- Simons Foundation
- Gordon and Betty Moore Foundation
Zitieren
APA
Yamada, K., Bixler, B., Sakurai, Y., Ashton, P. C., Sugiyama, J., Arnold, K., Begin, J., Corbett, L., Day-Weiss, S., Galitzki, N., Hill, C. A., Johnson, B. R., Jost, B., Kusaka, A., Koopman, B. J., Lashner, J., Lee, A. T., Mangu, A., Nishino, H., …, & Williams, P. A. (2024). The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes. Review of Scientific Instruments, 95(2). https://doi.org/10.1063/5.0178066
Vancouver
Yamada K, Bixler B, Sakurai Y, Ashton PC, Sugiyama J, Arnold K, et al. The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes. Review of Scientific Instruments. 2024;95(2). doi:10.1063/5.0178066
BibTeX
@article{Yamada2024,
author = {Yamada, K and Bixler, B and Sakurai, Y and Ashton, P C and Sugiyama, J and Arnold, K and Begin, J and Corbett, L and Day-Weiss, S and Galitzki, N and Hill, C A and Johnson, B R and Jost, B and Kusaka, A and Koopman, B J and Lashner, J and Lee, A T and Mangu, A and Nishino, H and Page, L A and Randall, M J and Sasaki, D and Song, X and Spisak, J and Tsan, T and Wang, Y and Williams, P A},
title = {The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes},
journal = {Review of Scientific Instruments},
year = {2024},
volume = {95},
number = {2},
doi = {10.1063/5.0178066}
}