EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

Masaaki Murata iD, Hironobu Nakata iD, Kengo Iijima iD, Shunsuke Adachi iD, Yudai Seino iD, Kenji Kiuchi iD, Frederick Matsuda iD, Michael J Randall iD, Kam Arnold iD, Nicholas Galitzki iD, Bradley R Johnson iD, Brian Keating iD und 7 weitere

Review of Scientific Instruments · 01.12.2023 · 94 (12)

DOI: 10.1063/5.0175099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 18.12.2023. Verfasst von Masaaki Murata und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Simons Foundation, Japan Society for the Promotion of Science, JSPS Core-to-Core Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

Autor:innen und Institutionen

  • Department of Physics, The University of Tokyo, Tokyo 113-0033, Japan.
  • Department of Physics, Kyoto University, Kitashirakawa Oiwake-cho, Sakyo-ku, Kyoto 606-8502, Japan.
  • Hakubi Center for Advanced Research, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-850, Japan.
  • Joseph Henry Laboratories of Physics, Jadwin Hall, Princeton University, Princeton, New Jersey 08544, USA.
  • Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (JAXA), Sagamihara, Kanagawa 252-5210, Japan.
  • Department of Physics, University of California, San Diego, La Jolla, California 92093, USA.

ORCID-Profile: Masaaki Murata, Hironobu Nakata, Kengo Iijima, Shunsuke Adachi, Yudai Seino, Kenji Kiuchi, Frederick Matsuda, Michael J Randall, Kam Arnold, Nicholas Galitzki, Bradley R Johnson, Brian Keating, Akito Kusaka, John B Lloyd, Joseph Seibert, Maximiliano Silva-Feaver, Osamu Tajima, Tomoki Terasaki, Kyohei Yamada

Förderung

  • Simons Foundation
  • Japan Society for the Promotion of Science
  • JSPS Core-to-Core Program
  • JST, The Establishment of University Fellowships Toward the Creation of Science Technology Innovation
  • U.S. Department of Energy, Office of Science, Office of High Energy Physics

Zitieren

APA

Murata, M., Nakata, H., Iijima, K., Adachi, S., Seino, Y., Kiuchi, K., Matsuda, F., Randall, M. J., Arnold, K., Galitzki, N., Johnson, B. R., Keating, B., Kusaka, A., Lloyd, J. B., Seibert, J., Silva-Feaver, M., Tajima, O., Terasaki, T., & Yamada, K. (2023). The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes. Review of Scientific Instruments, 94(12). https://doi.org/10.1063/5.0175099

Vancouver

Murata M, Nakata H, Iijima K, Adachi S, Seino Y, Kiuchi K, et al. The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes. Review of Scientific Instruments. 2023;94(12). doi:10.1063/5.0175099

BibTeX
@article{Murata2023,
  author = {Murata, Masaaki and Nakata, Hironobu and Iijima, Kengo and Adachi, Shunsuke and Seino, Yudai and Kiuchi, Kenji and Matsuda, Frederick and Randall, Michael J and Arnold, Kam and Galitzki, Nicholas and Johnson, Bradley R and Keating, Brian and Kusaka, Akito and Lloyd, John B and Seibert, Joseph and Silva-Feaver, Maximiliano and Tajima, Osamu and Terasaki, Tomoki and Yamada, Kyohei},
  title = {The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes},
  journal = {Review of Scientific Instruments},
  year = {2023},
  volume = {94},
  number = {12},
  doi = {10.1063/5.0175099}
}