Efficacy of 1-L versus 2-L polyethylene glycol plus ascorbate for bowel preparation: a multicenter, non-inferiority randomized trial in elderly outpatients: The PLATONE Study (on behalf of AIGO)
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S1001
DOI: 10.1055/s-0046-1822934 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von P Montalto und 13 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Adequate bowel cleansing is essential for a high-quality colonoscopy and directly impacts key quality indicators and clinical outcomes. A very low volume preparation based on 1L polyethylene glycol plus ascorbate (1L PEG+ASC) has been recently introduced. Nevertheless, the efficacy and safety of 1L PEG+ASC as compared to that of 2L PEG+ASC in elderly outpatients is still unclear.
Methods
This single-blinded, non-inferiority study randomized over-65 years old outpatients undergoing colonoscopy to receive split-dose 1L PEG+ASC or 2L PEG+ASC. The primary endpoint was the overall cleansing success (CS). Secondary endpoints were overall excellent cleansing (EC), adequate cleansing of the right colon, cecal intubation rate (CIR), adenoma detection rate (ADR), patient compliance, and safety.
Results
Overall, 285 patients (mean age 73.6±6.3 years) were randomized to 1L PEG+ASC (N=139) or 2L PEG+ASC (N=146). The total Boston-Bowel-Preparation-Scale (BBPS) score was significantly higher in the 1L compared with the 2L PEG+ASC group (7.66 vs 7.08; mean difference 0.58, 95% CI 0.17–0.98; P=0.005). The 1L PEG+ASC showed higher CS (94.2% vs 81.5%; OR 3.69, 95% CI 1.58–8.63; P=0.001) and EC rate (36.2% vs 24.7%; OR 1.74, 95% CI 1.05–2.89; P=0.034) as compared to the 2L PEG+ASC preparation. The cecal intubation rate was similar between the 1L and 2L PEG+ASC arms (95.7% vs 91.1%; OR 2.15, 95% CI 0.79–5.86; P=0.125). ADR was significantly higher in the 1L PEG+ASC group compared with the 2L PEG+ASC group (30.9% vs 19.9%; OR 1.80, 95% CI 1.04–3.12; P=0.033), while the colorectal cancer detection rate was similar between groups (1.4% vs 1.4%; OR 1.06, 95% CI 0.15–7.69; P=0.955). Tolerability and incidence of adverse events were comparable between preparations.
Conclusions
In elderly outpatients undergoing colonoscopy, 1L PEG+ASC was non-inferior and statistically superior to 2L PEG+ASC in achieving overall CS and EC, with a higher observed ADR, and comparable tolerability and safety. Further adequately powered studies are warranted to confirm the impact of 1L PEG+ASC preparation on lesion detection rates. Protocol Eudract N. 2020000927 38 Funding: Non conditional support by Norgine for supply and distribution of drugs. Publication History Article published online: 06 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Montalto, P., Vassallo, R., Maida, M., Lombardi, M., Cannizzaro, R., Segato, S., Fani, B., Balzarini, M., Maiero, S., Natali, A., Monica, F., Milazzo, G., Satta, P. U., & Bellini, M. (2026). Efficacy of 1-L versus 2-L polyethylene glycol plus ascorbate for bowel preparation: a multicenter, non-inferiority randomized trial in elderly outpatients: The PLATONE Study (on behalf of AIGO). Endoscopy, 58(S 03 S 03), S1001. https://doi.org/10.1055/s-0046-1822934
Vancouver
Montalto P, Vassallo R, Maida M, Lombardi M, Cannizzaro R, Segato S, et al. Efficacy of 1-L versus 2-L polyethylene glycol plus ascorbate for bowel preparation: a multicenter, non-inferiority randomized trial in elderly outpatients: The PLATONE Study (on behalf of AIGO). Endoscopy. 2026;58(S 03 S 03):S1001. doi:10.1055/s-0046-1822934
BibTeX
@article{Montalto2026,
author = {Montalto, P and Vassallo, R and Maida, M and Lombardi, M and Cannizzaro, R and Segato, S and Fani, B and Balzarini, M and Maiero, S and Natali, A and Monica, F and Milazzo, G and Satta, P Usai and Bellini, M},
title = {Efficacy of 1-L versus 2-L polyethylene glycol plus ascorbate for bowel preparation: a multicenter, non-inferiority randomized trial in elderly outpatients: The PLATONE Study (on behalf of AIGO)},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S1001},
doi = {10.1055/s-0046-1822934}
}
EUVIMED