Diagnostic accuracy of detective flow imaging endoscopic ultrasound in pancreatic lesions: a systematic review and meta-analysis
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S714
DOI: 10.1055/s-0046-1822033 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von F Antonini und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Pancreatic diseases are diagnostically challenging due to overlapping imaging features and variable lesion vascularity. While contrast-enhanced harmonic EUS (CH-EUS) improves microvascular visualization, its use is limited by cost and contraindications. Detective flow imaging EUS (DFI-EUS) is a novel, contrast-free Doppler technique with enhanced sensitivity for detecting fine vascular structures and slow blood flow. However, current evidence is limited to small, single-center studies with methodological variability, and its role relative to CH-EUS remains unclear. This meta-analysis aims to evaluate the diagnostic performance of DFI-EUS in pancreatic lesions. Methods we have conducted a systematic review and meta-analysis including MEDLINE (via PubMed), Scopus, and the Cochrane Library (Central Register of Controlled Trials), covering all available records up to 30 September 2025 (protocol registered on PROSPERO; registration number CRD420251086026).
Results
At the end of the selection process, four studies comprising a total of 267 patients were included in the meta-analysis. DFI demonstrated a pooled sensitivity of 0.93 (95% CI: 0.83–0.98) and a pooled specificity of 0.91 (95% CI: 0.47–0.99). Among these, two studies evaluated CE-EUS and eFLOW, reporting pooled sensitivity and specificity estimates of 0.96 and 0.94 for CE-EUS, and 0.84 and 0.69 for eFLOW, respectively.
Conclusions
This meta-analysis supports the diagnostic value of DFI-EUS for pancreatic lesions. These findings indicate that DFI shows robust discriminatory performance across the included datasets, although further validation with additional data would strengthen the generalizability of these results Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Antonini, F., Balducci, D., Vinci, A., Stigliano, S., Matteo, F. M. D., Montale, A., & Valvano, M. (2026). Diagnostic accuracy of detective flow imaging endoscopic ultrasound in pancreatic lesions: a systematic review and meta-analysis. Endoscopy, 58(S 03 S 03), S714. https://doi.org/10.1055/s-0046-1822033
Vancouver
Antonini F, Balducci D, Vinci A, Stigliano S, Matteo FMD, Montale A, et al. Diagnostic accuracy of detective flow imaging endoscopic ultrasound in pancreatic lesions: a systematic review and meta-analysis. Endoscopy. 2026;58(S 03 S 03):S714. doi:10.1055/s-0046-1822033
BibTeX
@article{Antonini2026,
author = {Antonini, F and Balducci, D and Vinci, A and Stigliano, S and Matteo, F M Di and Montale, A and Valvano, M},
title = {Diagnostic accuracy of detective flow imaging endoscopic ultrasound in pancreatic lesions: a systematic review and meta-analysis},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S714},
doi = {10.1055/s-0046-1822033}
}
EUVIMED