Polyp size measurement during real-time colonoscopy using a novel laser-based system

D Gerritsen, M van Riswijk, D K Rex, S A Gross, D Ben Ami Shor, N A Cohen, O Goldstein, S Odeh, M Spaander, A D Koch, V Rijckborst, P D Siersema

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S244

DOI: 10.1055/s-0046-1821046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von D Gerritsen und 11 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Problem to solve Colorectal polyp size is important for determining surveillance intervals, how to resect the polyp and whether to resect-and-discard the polyp. However, currently used polyp size measurement techniques are inaccurate and difficult to perform, highlighting the need for novel techniques. This international multicenter study evaluated the precision of visual assessment (VA) and biopsy forceps (BF)-assisted measurement compared to a novel laser-based measurement system during real-time colonoscopy. Innovation AccuMeasure (VTM Technologies, Haifa, Israel) is a novel laser-based measurement system to sub-mm–accurately perform 3D measurements during real-time colonoscopy. A previous ex vivo animal study showed this system to be more precise compared to VA with and without use of a BF. The system consists of a reusable through-the-scope (TTS) probe and a medical grade personal computer. The TTS probe inserted through the endoscope working channel projects a laser line across the polyp, enabling size measurement. Results A total of 137 polyps was successfully measured in 110 patients (56.4% male; median age 68 years (interquartile range (IQR): 18)). Colonoscopy indications were screening in 47 patients (42.7%), surveillance in 34 (30.9%), and diagnostic in 29 patients (26.4%). Most polyps were adenomas (n=91) or hyperplastic (n=23) and were equally distributed through the colon. The polyps were measured with the laser measurement system, VA, and BF in randomized order. The laser-based system achieved successful measurements in 68.8% of polyps, with a mean measurement time of 120 seconds (standard deviation (SD): 109.9). As shown in [ Table 1 ], failed measurements were due to technical malfunctions or difficulty aligning the laser with the polyp surface. Moderate agreement (Cohen kappa (k)=0.514) was observed between the laser-based system and VA, with VA wrongly assigning a polyp size to>5 mm (instead of≤5 mm) in 10 polyps (7.3%) and≥10 mm (instead of 5 mm (instead of≤5 mm) in 11 polyps (8.0%) and≥10 mm (instead of

Zitieren

APA

Gerritsen, D., Riswijk, M. V., Rex, D. K., Gross, S. A., Shor, D. B. A., Cohen, N. A., Goldstein, O., Odeh, S., Spaander, M., Koch, A. D., Rijckborst, V., & Siersema, P. D. (2026). Polyp size measurement during real-time colonoscopy using a novel laser-based system. Endoscopy, 58(S 03 S 03), S244. https://doi.org/10.1055/s-0046-1821046

Vancouver

Gerritsen D, Riswijk MV, Rex DK, Gross SA, Shor DBA, Cohen NA, et al. Polyp size measurement during real-time colonoscopy using a novel laser-based system. Endoscopy. 2026;58(S 03 S 03):S244. doi:10.1055/s-0046-1821046

BibTeX
@article{Gerritsen2026,
  author = {Gerritsen, D and Riswijk, M van and Rex, D K and Gross, S A and Shor, D Ben Ami and Cohen, N A and Goldstein, O and Odeh, S and Spaander, M and Koch, A D and Rijckborst, V and Siersema, P D},
  title = {Polyp size measurement during real-time colonoscopy using a novel laser-based system},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S244},
  doi = {10.1055/s-0046-1821046}
}
Kostenlos starten →