Comparative Diagnostic Performance of 19G Versus 22G Needles in EUS-Guided Liver Biopsy: A Systematic Review and Network Meta-Analysis
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S134-S135
DOI: 10.1055/s-0046-1820862 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von E Gadour und 14 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
This study aimed to determine the optimal needle type for endoscopic ultrasound-guided liver biopsy (EUS-LB) by comparing the diagnostic accuracy and specimen adequacy of various 19G and 22G fine-needle aspiration (FNA) and fine-needle biopsy (FNB) needles through a systematic review and network meta-analysis of randomized controlled trials (RCTs).
Methods
We conducted a network meta-analysis of five RCTs published between 2016 and 2022 in the USA, including 251 adult patients undergoing EUS-LB for parenchymal liver disease. The needles compared were 19G FNA, 19G Franseen FNB, 19G Fork-tip FNB, 22G Franseen FNB, and 22G Fork-tip FNB. Primary outcomes were total specimen length (mm) and number of complete portal tracts (CPTs).
Results
Both 19G Fork-tip and 19G Franseen FNB needles yielded significantly longer specimens compared to 22G Franseen FNB (MD 2.76 mm [95% CI 1.43 to 4.10] and 3.19 mm [2.07 to 4.31], respectively) and 22G Fork-tip FNB (MD 4.78 mm [0.95 to 8.62] and 5.21 mm [1.45 to 8.97], respectively). They also outperformed 19G FNA (MD 3.92 mm [0.51 to 7.33] and 3.49 mm [0.01 to 6.98], respectively). No significant difference was found between 19G FNA and 22G Franseen or Fork-tip needles. SUCRA rankings for specimen length favored 19G Franseen (0.91) and 19G Fork-tip (0.83). Regarding CPT count, 19G Franseen and 19G Fork-tip FNB significantly exceeded 22G Fork-tip FNB (MD 23.62 [5.25 to 41.98] and 22.80 [5.92 to 39.68], respectively) and 19G FNA (MD 21.50 [7.98 to 35.02] and 22.32 [6.98 to 37.65], respectively), with no significant difference compared to 22G Franseen FNB. SUCRA rankings for CPTs were 0.85 for 19G Fork-tip and 0.82 for 19G Franseen (Table 1). Diagnostic adequacy was higher with 19G Fork-tip (RR 6.61 [1.08 to 40.53]) and 19G Franseen (RR 8.50 [1.76 to 41.09]) compared to 22G Franseen FNB. Adverse events were rare, with only one gastric hematoma and mild abdominal pain episodes reported [ 1 ] [ 2 ].
Conclusions
The 19G end-cutting FNB needles (Franseen and Fork-tip) provide superior specimen length and portal tract yield compared to smaller gauge or FNA needles, supporting their preferential use in EUS-LB. These findings suggest larger caliber needles improve diagnostic quality without compromising safety. However, low evidence quality warrants further high-powered RCTs to confirm these results and guide clinical practice guidelines. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Gadour, E., Albeshir, M., Alqahtani, M., Crinò, S., Giuseppe, D., DONATELLI, G., Maida, M., Samanta, J., Dhar, J., Brigida, M., Marcello, S., Stasi, E., Aljahdli, E., Almuhaidb, A., & Facciorusso, A. (2026). Comparative Diagnostic Performance of 19G Versus 22G Needles in EUS-Guided Liver Biopsy: A Systematic Review and Network Meta-Analysis. Endoscopy, 58(S 03 S 03), S134-S135. https://doi.org/10.1055/s-0046-1820862
Vancouver
Gadour E, Albeshir M, Alqahtani M, Crinò S, Giuseppe D, DONATELLI G, et al. Comparative Diagnostic Performance of 19G Versus 22G Needles in EUS-Guided Liver Biopsy: A Systematic Review and Network Meta-Analysis. Endoscopy. 2026;58(S 03 S 03):S134-S135. doi:10.1055/s-0046-1820862
BibTeX
@article{Gadour2026,
author = {Gadour, E and Albeshir, M and Alqahtani, M and Crinò, S and Giuseppe, D and DONATELLI, G and Maida, M and Samanta, J and Dhar, J and Brigida, M and Marcello, S and Stasi, E and Aljahdli, E and Almuhaidb, A and Facciorusso, A},
title = {Comparative Diagnostic Performance of 19G Versus 22G Needles in EUS-Guided Liver Biopsy: A Systematic Review and Network Meta-Analysis},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S134--S135},
doi = {10.1055/s-0046-1820862}
}
EUVIMED