A systematic review and meta-analysis of diagnostic outcomes of endoscopic ultrasound guided liver biopsy versus percutaneous liver biopsy
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S160
DOI: 10.1055/s-0044-1783042 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von G. Rancatore und 9 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Despite the increasing diffusion of non-invasive tests for the diagnosis of liver diseases, histological assessment through liver biopsy (LB) is still often mandatory especially in unclear cases. Actually, percutaneous approach (PC-LB) is the gold standard. Nowadays, endoscopic ultrasound-guided liver biopsy (EUS-LB) has emerged as an established method to achieve liver tissue sampling. EUS-LB has several advantages such as: sampling of both liver lobes, it allows to obtain liver tissue sampling in case of ascites and toavoid damage to nearby organs and vessels. We performed a syematic review witj meta-analysis (MA) to evaluate the diagnostic outcomes and safety for liver tissue acquisition of PC-LB and EUS-LB in patients with liver diseases and focal liver lesions Methods Studies that compare diagnostic outcomes of PC-LB and EUS-LB were identified through literature search usign MEDLINE, Embase and Scopus until Septmber 2023 . MA was performed according to a frequentist approach. For technical success and accuracy, the untransformed proportions were estimated by the DerSimonian and Laird random-effects model.
Results
11 studies recruiting 1.389 patients of which 724 underwent PC-LB and 665 underwent EUS-L were included in MA. Overall, pooled diagnostic adequacy showed an OR 2.062 (95% CI: 0.360 – 11976 I 2 =71.4%, P=0.002) when comparing PC-LB to EUS-LB. Pooled accuracy between the two procedures was OR 3.071 (95% CI: 0.166 – 56.644 I 2 =64.47%, P=0.06). Pooled rate of overall adverse events was slightly higher in PC-LB compared to EUS-LB, OR: 1.297 (95% IC: 0.484 – 3.475 644 I 2 =35.34%, P=0.146. Overall no differences between the two procedures were observed I term of total length specimen and in term of complete portal tract.
Conclusions
In conclusion, our meta-analysis do not show significant differences between PC-LB and EUS-LB in terms of adequacy, technical success and accuracy, albeit EUS-LB is slightly safer than PC-LB Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Rancatore, G., Rizzo, G. M., Traina, M., Carrozza, L., Celsa, C., Ligresti, D., Dario, Q., Cabibbo, G., Marco, V. D., & Tarantino, I. (2024). A systematic review and meta-analysis of diagnostic outcomes of endoscopic ultrasound guided liver biopsy versus percutaneous liver biopsy. Endoscopy, 56(S 02 S 02), S160. https://doi.org/10.1055/s-0044-1783042
Vancouver
Rancatore G, Rizzo GM, Traina M, Carrozza L, Celsa C, Ligresti D, et al. A systematic review and meta-analysis of diagnostic outcomes of endoscopic ultrasound guided liver biopsy versus percutaneous liver biopsy. Endoscopy. 2024;56(S 02 S 02):S160. doi:10.1055/s-0044-1783042
BibTeX
@article{Rancatore2024,
author = {Rancatore, G. and Rizzo, G.E. M. and Traina, M. and Carrozza, L. and Celsa, C. and Ligresti, D. and Dario, Q. and Cabibbo, G. and Marco, V. Di and Tarantino, I.},
title = {A systematic review and meta-analysis of diagnostic outcomes of endoscopic ultrasound guided liver biopsy versus percutaneous liver biopsy},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S160},
doi = {10.1055/s-0044-1783042}
}