EUVIMEDEUVIMED entdecken
Crossref

Quantitative evaluation of reconstruction settings for FET-PET images using clinically based phantom models

A Chaban, J Ni, S Nekolla, I Yakushev

Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 170-171

DOI: 10.1055/s-0046-1818362 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von A Chaban und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: Tumor to background ratio (TBR) and biological tumor volume (BTV) are known to depend on image reconstruction parameters. Here, we studied the influence of reconstruction parameters using clinically based phantom models. Methodik/Methods: The study was performed on a Siemens Biograph Vision PET/CT using a 3D FET PET phantom built following FET intensity and distribution patterns of 50 primary diagnosedhigh-grade glioma patients. Two common tumor types were simulated: a) ring-like tumor (RLT): peripheral activity SUV=4.8 surrounding a central necrotic region with activity equal to background (SUV=1), and b) peak-like tumor (PLT): central core with SUV=4.8 and a surrounding peripheral zone with SUV=2.6. Both were embedded in a homogeneous background (SUV=1). All combinations of the following reconstruction parameters were evaluated: iterative ToF vs.TrueX ToF, Gaussian filter (GF) 4 mm vs. all-pass (AP), i.e., no filtering, and matrix size of 220×220 vs. 440×440. Lesions weresegmented using a threshold of 1.6×SUVmean. Ergebnisse/Results: TBRmean values were similar across thereconstructions, with TrueX-440-AP producing the mostaccurate values, followed by IT-440-AP. IT-440-GF recoveredTBRmax most accurately, followed by IT-220-GF and IT-440-AP. For the RLT, all reconstructions overestimated BTV by 21–32%, likely due to partial-volume effects on both inner and outer ring edges. The bias was most pronounced at 220 matrix size and with TrueX. The lowest bias was found for IT-440-AP. For the PLT, BTV was close to the ground truth across all reconstructions. Schlussfolgerungen/Conclusion: The choice of reconstruction parameters critically impacts FET-PET quantification. This is especially true for RLT, in which TBRmax is systematically overestimated by True-X and BTV by GF. Overall, IT-440-AP offers the best trade-off between accurately BTV, particularly in challenging RLT, and recovering TBRmax. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Chaban, A., Ni, J., Nekolla, S., & Yakushev, I. (2026). Quantitative evaluation of reconstruction settings for FET-PET images using clinically based phantom models. Nuklearmedizin - NuclearMedicine, 65(02), 170-171. https://doi.org/10.1055/s-0046-1818362

Vancouver

Chaban A, Ni J, Nekolla S, Yakushev I. Quantitative evaluation of reconstruction settings for FET-PET images using clinically based phantom models. Nuklearmedizin - NuclearMedicine. 2026;65(02):170-171. doi:10.1055/s-0046-1818362

BibTeX
@article{Chaban2026,
  author = {Chaban, A and Ni, J and Nekolla, S and Yakushev, I},
  title = {Quantitative evaluation of reconstruction settings for FET-PET images using clinically based phantom models},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2026},
  volume = {65},
  number = {02},
  pages = {170--171},
  doi = {10.1055/s-0046-1818362}
}
Kostenlos starten →