Deep Learning-Based CT-free Attenuation Correction Using a Next Generation 148cm LAFOV PET System: Initial Experience
Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 149-150
DOI: 10.1055/s-0046-1818303 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von P Rath und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Ziel/Aim: We tested a manufacturer-designed, AI-driven algorithm for PET-based generation of attenuation maps and subsequent reconstruction of CT-free attenuation-corrected F-18-FDG LAFOVPET images. This may alleviate the need for low-dose CT and it may eliminate adverse effects of PET/CT misalignment. Methodik/Methods: Using the Panorama GS 148cm LAFOV PET/CT (United Imaging Healthcare), 10 patients with various malignancies underwent a 5min F-18-FDG scan (standard dose, 3 MBq/kg bodyweight) and low-dose CT for AC during shallow breathing. Two static image datasets were reconstructed using OSEM iterative algorithm: First, the standard PET images using AC from CT, and second, PET images using the AI-based, manufacturer-provided CT-free AC. Automated CT-based organ segmentation was employed to determine SUVmean in multiple organs (liver, lungs, spleen, kidneys and bones). Coefficient of Variation (CoV) for SUV mean of organ VOIs was used as a measure of background noise. Lesion signal strength was measured by SUVpeak and SUVmax in lesions within 15cm from the diaphragm and lesions more distant from the diaphragm (2 per subject): For comparison of both AC algorithms, relative ratios (e.g. SUVAI-based/SUVCT-based) were obtained. Ergebnisse/Results: Ratios of SUVmean ranged from 0.88-1.1 for all organ VOIs. Organ-related CoV showed ratios of about 0.99-1.1 for liver, spleen and bone, and 0.93 and 1.09 for kidneys and lungs, respectively. Ratios of lesional SUVpeak were 0.85-1.23 for diaphragm-near lesions and 0.87-1.04 for lesions distant from the diaphragm. Ratios of lesional SUVmax was at most 0.65-1.23 and 0.86-1.16, respectively. Schlussfolgerungen/Conclusion: CT-free AC has no major effect on and uptake measurements and background noise in organs. When compared to CT-based AC, however, differences in signal strength may be observed for lesions close to the diaphragm.. This may be caused by potential misalignment between CT and PET in CT-based AC. These initial data support feasibility of the novel dose-sparing approach, and serve as a stimulus for further investigation. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Rath, P., Kröhn, S., Nikoukar, L. R., Weiberg, D., Uhlemann, A., Henning, K., Bengel, F., & Ziegler, S. (2026). Deep Learning-Based CT-free Attenuation Correction Using a Next Generation 148cm LAFOV PET System: Initial Experience. Nuklearmedizin - NuclearMedicine, 65(02), 149-150. https://doi.org/10.1055/s-0046-1818303
Vancouver
Rath P, Kröhn S, Nikoukar LR, Weiberg D, Uhlemann A, Henning K, et al. Deep Learning-Based CT-free Attenuation Correction Using a Next Generation 148cm LAFOV PET System: Initial Experience. Nuklearmedizin - NuclearMedicine. 2026;65(02):149-150. doi:10.1055/s-0046-1818303
BibTeX
@article{Rath2026,
author = {Rath, P and Kröhn, S and Nikoukar, L R and Weiberg, D and Uhlemann, A and Henning, K and Bengel, F and Ziegler, S},
title = {Deep Learning-Based CT-free Attenuation Correction Using a Next Generation 148cm LAFOV PET System: Initial Experience},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2026},
volume = {65},
number = {02},
pages = {149--150},
doi = {10.1055/s-0046-1818303}
}
EUVIMED