Assessing Brain PET Systems – Brain EARL and NEMA NU2 2018 Performance Evaluation of the NeuroLF "Pro" System

B Sattler, I Sacco, E Mikhaylova, U Bechler, T Scholz, M Ahnen, H Barthel, M Jehl, M Rullmann, E Stokman, J Streb, S Tiepolt und 2 weitere

Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 124

DOI: 10.1055/s-0046-1818233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von B Sattler und 13 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: This work presents the performance evaluation of the NeuroLF Pro (Positrigo AG, Zürich Switzerland), a compact seated dedicated brain PET system. It’s detection ring is based on 12288 15-mm-thick LYSO crystals (3.19 x 3.19 mm) with an axial field of view (FOV) of 16.3 cm and a transaxial FOV of 26.8 cm. Methodik/Methods: The measurements and analysis were performed following the NEMA NU 2-2018 protocol. Image contrast has been evaluated using an adapted IQ Phantom (the Esser Phantom) with hot vials of 25-, 16-, 12-, and 8-mm diameter in a warm background, activity ratio of 4.1/1. Moreover, the calibration and image quality has been assessed following the EARL accreditation protocol for brain PET systems [ 1 ] Ergebnisse/Results: The average filtered-back-projection NU2 spatial resolution, measured at 1 cm and 10 cm radial offsets, was found to be 2.72 mm and 3.8 mm, respectively. NeuroLF Pro showed good image contrast for hot vials in a warm background, achieving values of 81%, 61.9%, 49.6%, and 26.9%, respectively, with a maximum background variability of 9% for the 8-mm-diameter vial. NU2 Sensitivity, evaluated using a 70-cm-long line source, was measured at 10.26 cps/kBq at the center of the field of view and 14.31 cps/kBq at a 10 cm radial offset. Schlussfolgerungen/Conclusion: These findings underline that NeuroLF Pro delivers high-quality brain PET imaging with solid detection efficiency and quantitative stability. Although the system operates without CT-based attenuation correction, it is designed for clinical environments pursuing accreditations, including the EARL Brain PET harmonization framework. An expanded EARL program specifically addressing dedicated (seated) brain PET systems is under development. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Sattler, B., Sacco, I., Mikhaylova, E., Bechler, U., Scholz, T., Ahnen, M., Barthel, H., Jehl, M., Rullmann, M., Stokman, E., Streb, J., Tiepolt, S., Fischer, J., & Sabri, O. (2026). Assessing Brain PET Systems – Brain EARL and NEMA NU2 2018 Performance Evaluation of the NeuroLF "Pro" System. Nuklearmedizin - NuclearMedicine, 65(02), 124. https://doi.org/10.1055/s-0046-1818233

Vancouver

Sattler B, Sacco I, Mikhaylova E, Bechler U, Scholz T, Ahnen M, et al. Assessing Brain PET Systems – Brain EARL and NEMA NU2 2018 Performance Evaluation of the NeuroLF "Pro" System. Nuklearmedizin - NuclearMedicine. 2026;65(02):124. doi:10.1055/s-0046-1818233

BibTeX
@article{Sattler2026,
  author = {Sattler, B and Sacco, I and Mikhaylova, E and Bechler, U and Scholz, T and Ahnen, M and Barthel, H and Jehl, M and Rullmann, M and Stokman, E and Streb, J and Tiepolt, S and Fischer, J and Sabri, O},
  title = {Assessing Brain PET Systems – Brain EARL and NEMA NU2 2018 Performance Evaluation of the NeuroLF "Pro" System},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2026},
  volume = {65},
  number = {02},
  pages = {124},
  doi = {10.1055/s-0046-1818233}
}
Kostenlos starten →