Permanent Pacemaker Dependency after Transcatheter Aortic Valve Implantation (TAVI): Comparison of Self-Expanding and Balloon-Expandable Prostheses
The Thoracic and Cardiovascular Surgeon · 01.01.2026 · 74 (S 01 S 01) · S1-S70
DOI: 10.1055/s-0046-1817332 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.01.2026. Verfasst von S. Huppertz und 12 weiteren Autor:innen.
Abstract (Originalsprache)
All articles of this category (opens in new window)
Background
Conduction disturbances requiring permanent pacemaker implantation (PPI) are frequent after transcatheter aortic valve implantation (TAVI) and represent a continued concern. The extent of mid-term pacemaker dependency and pacing burden remains unclear.
Methods
This retrospective, single-center study included 2.630 consecutive patients receiving TAVI between 2016 and 2022. A total of 281 patients (self-expanding valve [SEV] n = 162; balloon-expandable valve [BEV] n = 119) who required new pacemaker implantation following TAVI underwent rhythm analysis. The cohort was analyzed for atrial fibrillation (AF), complete right bundle branch block (RBBB), first-degree AV block (AV I degrees), and postdilatation. Mid-term conduction disturbances and pacing burden after self-expanding (SEV) and balloon-expandable valves (BEV) were assessed for comparative analysis.
Results
Preinterventional rhythm disturbances at baseline were distributed as follows for SEV vs. BEV: AF 43.8% vs. 47.1% ( p = .591), RBBB 24.1% vs. 0.0% ( p < .001), AV I degrees 16.0% vs. 1.7% ( p < .001). Postdilatation was more common in SEV (21.3% vs. 6.0%; p < .001). Postimplant high-degree AV block occurred in 24.6% after SEV and 9.6% after BEV ( p = .039). PPI was required more often after SEV (12%) than after BEV (9.1%). Combined mean pacing burden decreased from 80.4% early to 48.0% by 12 months. Values stratified by SEV/BEV were as follows: 83.1%/77.6%, 61.7%/62.8%, 56.0%/48.7%, 45.6%/50.8% at 0 to 14/30 to 50/120 to 150, and 330 to 400 days.
Conclusion
AF, RBBB, AV I degrees, and postdilatation are frequent in patients at risk for conduction disturbances after TAVI and may guide early PPI decisions, but their association with mid-term pacing dependency appears coincidental, as pacing burden declined to 48.0% by 12 months. Pacing burden reduction was similar between valve types, reflecting parallel mid-term AV-conduction recovery. Further analyses are needed to predict true pacing burden at follow-up. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Huppertz, S., Haffke, Y., Chigri, A., Gassa, A., Wienemann, H., Djordjevic, I., Lee, S., Mauri, V., Adam, M., Baldus, S., Gerfer, S., Conradi, L., & Kuhn, E. (2026). Permanent Pacemaker Dependency after Transcatheter Aortic Valve Implantation (TAVI): Comparison of Self-Expanding and Balloon-Expandable Prostheses. The Thoracic and Cardiovascular Surgeon, 74(S 01 S 01), S1-S70. https://doi.org/10.1055/s-0046-1817332
Vancouver
Huppertz S, Haffke Y, Chigri A, Gassa A, Wienemann H, Djordjevic I, et al. Permanent Pacemaker Dependency after Transcatheter Aortic Valve Implantation (TAVI): Comparison of Self-Expanding and Balloon-Expandable Prostheses. The Thoracic and Cardiovascular Surgeon. 2026;74(S 01 S 01):S1-S70. doi:10.1055/s-0046-1817332
BibTeX
@article{Huppertz2026,
author = {Huppertz, S. and Haffke, Y. and Chigri, A. and Gassa, A. and Wienemann, H. and Djordjevic, I. and Lee, S. and Mauri, V. and Adam, M. and Baldus, S. and Gerfer, S. and Conradi, L. and Kuhn, E.},
title = {Permanent Pacemaker Dependency after Transcatheter Aortic Valve Implantation (TAVI): Comparison of Self-Expanding and Balloon-Expandable Prostheses},
journal = {The Thoracic and Cardiovascular Surgeon},
year = {2026},
volume = {74},
number = {S 01 S 01},
pages = {S1--S70},
doi = {10.1055/s-0046-1817332}
}
EUVIMED