EUVIMEDEUVIMED entdecken
Crossref

Prevention of Driveline Infections in Left Ventricular Assist Device Patients Using Closed Incision Negative Pressure Therapy

E. Deniz, J. Hanke, A. Merzah, Z. Darbaidze, M. Biewer, S. Knigge, K. Homann, G. Dogan, B. Schmack, A. Weymann, JD. Schmitto, A. Ruhparwar

The Thoracic and Cardiovascular Surgeon · 01.01.2026 · 74 (S 01 S 01) · S1-S70

DOI: 10.1055/s-0046-1817288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.01.2026. Verfasst von E. Deniz und 11 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

All articles of this category (opens in new window)

Background

Driveline infections (DLI) are the most common type of VAD-associated adverse events, with an incidence of up to 30% among patients supported by the newest generation left ventricular assist device. The curative treatment of DLI is challenging, and infection-related adverse events such as stroke and multi-organ failure can severely affect patient survival. Thus, prevention of DLI is of critical importance. Closed incision negative pressure therapy (cINPT) is a preventive approach to wound infections that has been proven to significantly reduce the occurrence of chronic, infectious wounds, for example, in patients after sternotomy. However, its effect on DLI has not been investigated. We present the results of the first cohort of LVAD patients treated by cINPT for the prevention of DLI.

Methods

The cINPT was used in 32 consecutive patients following VAD implantation. The negative pressure wound care system was applied on the driveline immediately after VAD implantation and applied for 14 days with continuous negative pressures of −125 mmHg to the driveline exit site. The condition of the wound and the surrounding skin was evaluated immediately after the removal of the incisional wound system and before the patient’s discharge. Baseline characteristics, laboratory, and microbiological results were recorded. The postinterventional wound was scored by a DL exit site assessment tool.

Results

A total of 1,117 days on device (DOD, 3.06 patient years) were observed. All patients (32/32) were supported by the newest generation LVAD. Follow-up was 100% complete. 93.75% of patients (30/32) presented with entirely healed wounds, and no skin damage around the wound after removal of the wound system on POD 14. In 6.25% of the cases (2/32), minor wound secretion was observed. None of the cases showed laboratory or microbiological signs of wound infection until discharge. Mean score on the exit site assessment tool was 1.06 (range: 1–2).

Conclusion

Treatment of the driveline exit site in VAD patients with a closed incision wound management system and negative pressure is feasible and associated with improved wound healing in the postoperative course after LVAD implantation. It is a promising tool for the prevention of DLI. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Deniz, E., Hanke, J., Merzah, A., Darbaidze, Z., Biewer, M., Knigge, S., Homann, K., Dogan, G., Schmack, B., Weymann, A., Schmitto, J., & Ruhparwar, A. (2026). Prevention of Driveline Infections in Left Ventricular Assist Device Patients Using Closed Incision Negative Pressure Therapy. The Thoracic and Cardiovascular Surgeon, 74(S 01 S 01), S1-S70. https://doi.org/10.1055/s-0046-1817288

Vancouver

Deniz E, Hanke J, Merzah A, Darbaidze Z, Biewer M, Knigge S, et al. Prevention of Driveline Infections in Left Ventricular Assist Device Patients Using Closed Incision Negative Pressure Therapy. The Thoracic and Cardiovascular Surgeon. 2026;74(S 01 S 01):S1-S70. doi:10.1055/s-0046-1817288

BibTeX
@article{Deniz2026,
  author = {Deniz, E. and Hanke, J. and Merzah, A. and Darbaidze, Z. and Biewer, M. and Knigge, S. and Homann, K. and Dogan, G. and Schmack, B. and Weymann, A. and Schmitto, JD. and Ruhparwar, A.},
  title = {Prevention of Driveline Infections in Left Ventricular Assist Device Patients Using Closed Incision Negative Pressure Therapy},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2026},
  volume = {74},
  number = {S 01 S 01},
  pages = {S1--S70},
  doi = {10.1055/s-0046-1817288}
}
Kostenlos starten →