EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical outcomes of modified left ventricular assist device driveline management

Shusuke Imaoka, Noriyuki Kashiyama, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Ryohei Matsuura, Yusuke Misumi, Koichi Toda, Shigeru Miyagawa

Journal of Artificial Organs · 2025-06 · 28 (2) · 207-215

DOI: 10.1007/s10047-024-01482-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Artificial Organs, online erschienen am 18.12.2024. Verfasst von Shusuke Imaoka und 9 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Shi, Osaka, Osaka fu, 565-0871, Japan. s-i…. Hauptthemen laut MEDLINE: Heart-Assist Devices, Heart Failure, Prosthesis-Related Infections, Prosthesis Implantation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Osaka University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site ( n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement ( n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method ( p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHeart FailureProsthesis-Related InfectionsProsthesis ImplantationHumansRetrospective StudiesMaleFemaleMiddle AgedAgedTreatment OutcomeAdultJapanProsthesis Design

Stichwörter der Autor:innen

Drive line infectionLeft ventricular assist deviceLeft ventricular assist device drive line

Autor:innen und Institutionen

  • Departments of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Shi, Osaka, Osaka fu, 565-0871, Japan. s-imaoka@surg1.med.osaka-u.ac.jp.
  • Departments of Cardiovascular Surgery, Fukui Cardiovascular Hospital, Fukui, Japan.
  • Departments of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Shi, Osaka, Osaka fu, 565-0871, Japan. djason55@gmail.com.
  • Departments of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Shi, Osaka, Osaka fu, 565-0871, Japan.
  • Department of thoracic and cardiovascular surgery, Dokkyo Medical University Saitama Medical Center, Saitama, Japan.

Förderung

  • Osaka University

Zitieren

APA

Imaoka, S., Kashiyama, N., Yoshioka, D., Saito, S., Kawamura, T., Kawamura, A., Matsuura, R., Misumi, Y., Toda, K., & Miyagawa, S. (2025). Clinical outcomes of modified left ventricular assist device driveline management. Journal of Artificial Organs, 28(2), 207-215. https://doi.org/10.1007/s10047-024-01482-8

Vancouver

Imaoka S, Kashiyama N, Yoshioka D, Saito S, Kawamura T, Kawamura A, et al. Clinical outcomes of modified left ventricular assist device driveline management. Journal of Artificial Organs. 2025;28(2):207-215. doi:10.1007/s10047-024-01482-8

BibTeX
@article{Imaoka2025,
  author = {Imaoka, Shusuke and Kashiyama, Noriyuki and Yoshioka, Daisuke and Saito, Shunsuke and Kawamura, Takuji and Kawamura, Ai and Matsuura, Ryohei and Misumi, Yusuke and Toda, Koichi and Miyagawa, Shigeru},
  title = {Clinical outcomes of modified left ventricular assist device driveline management},
  journal = {Journal of Artificial Organs},
  year = {2025},
  volume = {28},
  number = {2},
  pages = {207--215},
  doi = {10.1007/s10047-024-01482-8}
}