EUVIMEDEUVIMED entdecken
Crossref

Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study

Daniel M G Perez Neto iD, Leonardo A L Muzzi iD, Fábio L Santos iD, Ruthnea A L Muzzi iD, Fernando Y K Kawamoto iD, Luciane R Mesquita iD, Bruno W Minto iD

Veterinary and Comparative Orthopaedics and Traumatology · 01.07.2025 · 38 (04) · 171-177

DOI: 10.1055/s-0044-1800818 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.07.2025. Verfasst von Daniel M G Perez Neto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine, Federal University of Lavras (UFLA), University Campus, Lavras, Minas Gerais, Brazil. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Femur. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Reabilitech.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objective of this study was to assess the stability of the femoral component of a hip resurfacing arthroplasty prosthesis in canine cadaveric bone using a biomechanical test. Study Design Twenty adult dog cadavers were utilized, from which both femoral bones were extracted and preserved for experimentation. For each pair of femurs from the same animal, one femur underwent implantation of the hip resurfacing arthroplasty prosthesis, while the contralateral femur remained intact. All femoral specimens underwent flexo-compression biomechanical testing, with variables including maximum load (ML), load at collapse (LC), displacement at maximum load (DML), displacement at collapse (DC), and stiffness (k) being analysed. Subsequent to the biomechanical evaluation, the femoral specimens were radiographed to assess failure behaviour.

Results

The prosthesis group showed a reduction of 22% (p ≤ 0.050) for the ML variable and 27% (p ≤ 0.05) for LC values. The prosthetic group supported a mean ML equivalent to six times the body weight of the animals whose bones were tested. No significant disparities were detected between the groups for the other analysed variables (DML, DC, and k). Similar failure patterns, such as fractures in the femoral neck region, were observed in specimens from both groups.

Conclusion

The hip resurfacing arthroplasty prosthesis demonstrated biomechanical performance with no differences in DML, DC, and k but showed inferior performance in ML and LC when compared with intact femurs in the ex vivo setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisFemurAnimalsDogsBiomechanical PhenomenaCadaverMale

Autor:innen und Institutionen

  • Department of Veterinary Medicine, Federal University of Lavras (UFLA), University Campus, Lavras, Minas Gerais, Brazil.
  • Department of Engineering, Federal University of Lavras (UFLA), University Campus, Lavras, Minas Gerais, Brazil.
  • Department of Veterinary Medicine, Lavras University (Unilavras), Lavras, Minas Gerais, Brazil.
  • Department of Clinic and Veterinary Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University (UNESP), Botucatu, Sao Paulo, Brazil.
  • Department of Clinic and Veterinary Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University (UNESP), Jaboticabal, Sao Paulo, Brazil.

ORCID-Profile: Daniel M G Perez Neto, Leonardo A L Muzzi, Fábio L Santos, Ruthnea A L Muzzi, Fernando Y K Kawamoto, Luciane R Mesquita, Bruno W Minto

Förderung

  • Reabilitech

Zitieren

APA

Perez Neto, D. M. G., Muzzi, L. A. L., Santos, F. L., Muzzi, R. A. L., Kawamoto, F. Y. K., Mesquita, L. R., & Minto, B. W. (2025). Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study. Veterinary and Comparative Orthopaedics and Traumatology, 38(04), 171-177. https://doi.org/10.1055/s-0044-1800818

Vancouver

Perez Neto DMG, Muzzi LAL, Santos FL, Muzzi RAL, Kawamoto FYK, Mesquita LR, et al. Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study. Veterinary and Comparative Orthopaedics and Traumatology. 2025;38(04):171-177. doi:10.1055/s-0044-1800818

BibTeX
@article{PerezNeto2025,
  author = {Perez Neto, Daniel M G and Muzzi, Leonardo A L and Santos, Fábio L and Muzzi, Ruthnea A L and Kawamoto, Fernando Y K and Mesquita, Luciane R and Minto, Bruno W},
  title = {Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2025},
  volume = {38},
  number = {04},
  pages = {171--177},
  doi = {10.1055/s-0044-1800818}
}
Kostenlos starten →