EUVIMEDEUVIMED entdecken
Crossref

Complications and Long-Term Outcome in 30 Canine Total Hip Arthroplasties Using a Second-Generation Selective Laser Melted Screw Cup

Nikolaus Huels, Philipp Dautzenberg, Dana Keim, Oliver Harms, Johannes Siedenburg

Veterinary and Comparative Orthopaedics and Traumatology · 01.03.2025 · 38 (02) · 057-062

DOI: 10.1055/s-0044-1789264 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.03.2025. Verfasst von Nikolaus Huels und 4 weiteren Autor:innen. Beteiligte Einrichtung: Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Hannover, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Dog Diseases, Postoperative Complications, Hip Prosthesis. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to report complications and outcomes of a cementless total hip arthroplasty (THA) system with a second-generation selective laser-melted screw cup (SCSL). Study Design All THA using the SCSL performed at a single institution between January 2017 and November 2022 were retrospectively evaluated. Patients with a minimum follow-up period of 12 months and complete medical records were included and analyzed for radiographic and clinical outcomes.

Results

Thirty THA with SCSL in 23 dogs were included in this study. Complications were observed in seven hips, comprising two minor and five major complications, with two hips experiencing two major complications. Among these seven major complications, six were associated with the femoral implant and one involved cup luxation. Of the 30 THA, 4 were explanted, while 26 remained in place for a median follow-up of 17.5 months (range, 12–38 months).

Conclusion

No cases of late aseptic loosening were observed with SCSL. THA using SCSL helps reduce cup-associated complications and is appropriate for THA surgery, and the overall complication rate is comparable with that of other single-implant systems. Nevertheless, four hips were explanted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipDog DiseasesPostoperative ComplicationsHip ProsthesisBone ScrewsDogsAnimalsRetrospective StudiesMaleFemaleTreatment OutcomeLasers

Autor:innen und Institutionen

  • Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Hannover, Germany.
  • Kleintierzentrum alte Druckerei, Herzogenrath, Germany.
  • Tierärztliche Klinik Gessertshausen Altano GmbH, Gessertshausen, Germany.
  • Fachzentrum für Kleintiermedizin, Langenhagen, Germany.

Zitieren

APA

Huels, N., Dautzenberg, P., Keim, D., Harms, O., & Siedenburg, J. (2025). Complications and Long-Term Outcome in 30 Canine Total Hip Arthroplasties Using a Second-Generation Selective Laser Melted Screw Cup. Veterinary and Comparative Orthopaedics and Traumatology, 38(02), 057-062. https://doi.org/10.1055/s-0044-1789264

Vancouver

Huels N, Dautzenberg P, Keim D, Harms O, Siedenburg J. Complications and Long-Term Outcome in 30 Canine Total Hip Arthroplasties Using a Second-Generation Selective Laser Melted Screw Cup. Veterinary and Comparative Orthopaedics and Traumatology. 2025;38(02):057-062. doi:10.1055/s-0044-1789264

BibTeX
@article{Huels2025,
  author = {Huels, Nikolaus and Dautzenberg, Philipp and Keim, Dana and Harms, Oliver and Siedenburg, Johannes},
  title = {Complications and Long-Term Outcome in 30 Canine Total Hip Arthroplasties Using a Second-Generation Selective Laser Melted Screw Cup},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2025},
  volume = {38},
  number = {02},
  pages = {057--062},
  doi = {10.1055/s-0044-1789264}
}