The influence of cochlear morphology on residual hearing and electrode array design on residual hearing preservation
Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S260
DOI: 10.1055/s-0044-1784861 ↗Kurz gefasst
Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Ann-Sophie Kremp Leonie und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
In order to individualize cochlea implant surgery regarding cochlear morphology, different electrode arrays have been developed. The aim of the study is to investigate the influence of the electrode array design concerning intracochlear trauma and residual hearing preservation. Furthermore, we intend to examine the influence of cochlear morphology on preoperative residual hearing.
Methods
We conducted a retrospective analysis of 1005 patients who underwent implantation between 2003 and 2019 using the Contour Advance, slim straight (SSA), and slim modiolar electrode array from CochlearTM, and the Flex24, 26, 28, and Soft electrode array from MED EL. Digital volume tomography was employed to measure cochlear morphology, including measurements for distance A, B, and height, as well as scalar position. Audiological outcomes and Freiburger monosyllables were compared to preoperative performance and then contrasted based on the electrode array design and cochlear size.
Results
Preoperative residual hearing showed an increase with larger cochlear size, although this increase lacked statistical significance. The SSA and the Flex24 electrode array demonstrated the least cochlear trauma and the most favorable performance in terms of preserving residual hearing.
Conclusion
The study emphasizes the significant influence of electrode array design on intracochlear trauma and the preservation of residual hearing. For patients with existing residual hearing, it is advisable to choose slim and atraumatic electrode arrays, especially the SSA and the Flex24. In cases involving residual hearing, the preferable approach involves round window insertion without extension. Moreover, the cochlear size appears to exhibit a positive trend in relation to preoperative residual hearing. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Leonie, A. K., Everad, F., Beck, R., Aschendorff, A., Arndt, S., & Ketterer, M. C. (2024). The influence of cochlear morphology on residual hearing and electrode array design on residual hearing preservation. Laryngo-Rhino-Otologie, 103(S 02 S 02), S260. https://doi.org/10.1055/s-0044-1784861
Vancouver
Leonie AK, Everad F, Beck R, Aschendorff A, Arndt S, Ketterer MC. The influence of cochlear morphology on residual hearing and electrode array design on residual hearing preservation. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S260. doi:10.1055/s-0044-1784861
BibTeX
@article{Leonie2024,
author = {Leonie, Ann-Sophie Kremp and Everad, Friederike and Beck, Rainer and Aschendorff, Antje and Arndt, Susan and Ketterer, Manuel Christoph},
title = {The influence of cochlear morphology on residual hearing and electrode array design on residual hearing preservation},
journal = {Laryngo-Rhino-Otologie},
year = {2024},
volume = {103},
number = {S 02 S 02},
pages = {S260},
doi = {10.1055/s-0044-1784861}
}
EUVIMED