EUVIMEDEUVIMED entdecken
Crossref

Safety and coupling efficiency of round window vibroplasty

Nicole Knölke, Susan Busch, Hannes Maier, Thomas Lenarz

Laryngo-Rhino-Otologie · 01.05.2024 · 103 (S 02 S 02) · S244-S245

DOI: 10.1055/s-0044-1784804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laryngo-Rhino-Otologie, erschienen am 01.05.2024. Verfasst von Nicole Knölke und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Since 2005 the Floating Mass Transducer (FMT) of the Vibrant Soundbridge (VSB) can be coupled directly or indirectly to the round window. Indirect coupling can be done via fascia, Tutopatch (TP), Round Window Coupler (RWC), Round Window Soft Coupler (RWS), or the CMD Hannover Coupler (HCV2). The aim of the study is (1) analyzing the safety of the RW vibroplasty and (2) the evaluation of the coupling efficiency. Material and Methods Inclusion criteria was a bone conduction threshold (BC) within the indication limit for RW vibroplasty+10 dB and within the measurement limit. Safety analysis included revision and explantation rates. The audiological results included BC and the coupling efficiency (CEF, in situ measurement - BC). The results were analyzed pre- and postoperatively after 2 month (2m), 2.7 (2y) and 5.4 (5y) years. The average is given as PTA 4 .

Results

The audiological analysis (n=56) showed a significant change in mean BC at 2y in groups HCV2 ( n =12) and RWS ( n =8) by 8.14 dB and 5.9 dB, respectively. Regarding safety analysis (n=76), 9 patients were explanted (n=3 deficit, n=2 implant defect, n=2 infections, n=2 cholesteatoma), 6 of whom received VSB reimplantation (n=5 RW vibroplasty) and the others acoustic implants (BAHA, Bonebridge, CODACS). Revisions (n=4) were caused by deficit (n=2) and medical reasons (n=1 related, n=2 non-related). A significant improvement in CEF was found at 5y for group RWC (n=14) at 4 and 6 kHz. A CEF of>35dB was found in 5 subjects (n=4 TP, n=1 HCV2) with a BC of 16.5 dB HL. No significant differences were found between the groups in terms of safety or CEF.

Discussion

The RW vibroplasty is a safe procedure. The coupling efficiency becomes more important the further the hearing loss progresses. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Knölke, N., Busch, S., Maier, H., & Lenarz, T. (2024). Safety and coupling efficiency of round window vibroplasty. Laryngo-Rhino-Otologie, 103(S 02 S 02), S244-S245. https://doi.org/10.1055/s-0044-1784804

Vancouver

Knölke N, Busch S, Maier H, Lenarz T. Safety and coupling efficiency of round window vibroplasty. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S244-S245. doi:10.1055/s-0044-1784804

BibTeX
@article{Knlke2024,
  author = {Knölke, Nicole and Busch, Susan and Maier, Hannes and Lenarz, Thomas},
  title = {Safety and coupling efficiency of round window vibroplasty},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S244--S245},
  doi = {10.1055/s-0044-1784804}
}
Kostenlos starten →