EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling

Daniel Dejaco, David Riedl, Timo Maria Gottfried, Matthias Santer, Annette Runge, Josef Seebacher, Philipp Zelger, Bicego Lia, Schmutzhard Joachim

European Archives of Oto-Rhino-Laryngology · 2024-01 · 281 (1) · 141-151

DOI: 10.1007/s00405-023-08103-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 13.07.2023. Verfasst von Daniel Dejaco und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria. Hauptthemen laut MEDLINE: Hearing Loss, Mixed Conductive-Sensorineural, Ossicular Prosthesis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MED-EL Medical Electronics, University of Innsbruck and Medical University of Innsbruck.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as “Vibroplasty”. Sufficient transfer of the VSB’s floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty.

Methods

This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3.

Results

A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η 2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold.

Conclusion

Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hearing Loss, Mixed Conductive-SensorineuralOssicular ProsthesisHumansProspective StudiesEvoked Potentials, Auditory, Brain StemAuditory ThresholdTreatment Outcome

Stichwörter der Autor:innen

Coupling-qualityIntraoperative auditory-brainstem-responsesMild-to-profound hearing lossOtologyOutcomeVibroplasty

Autor:innen und Institutionen

  • Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.
  • Department of Medical Psychology, Medical University of Innsbruck, Schöpfstr. 23a, 6020, Innsbruck, Austria.
  • Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.
  • MED-EL Elektromedizinische Geräte G.M.B.H., Fürstenweg 77a, 6020, Innsbruck, Austria.
  • Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria. joachim.schmutzhard@i-med.ac.at.

Förderung

  • MED-EL Medical Electronics
  • University of Innsbruck and Medical University of Innsbruck

Zitieren

APA

Dejaco, D., Riedl, D., Gottfried, T. M., Santer, M., Runge, A., Seebacher, J., Zelger, P., Lia, B., & Joachim, S. (2024). The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling. European Archives of Oto-Rhino-Laryngology, 281(1), 141-151. https://doi.org/10.1007/s00405-023-08103-9

Vancouver

Dejaco D, Riedl D, Gottfried TM, Santer M, Runge A, Seebacher J, et al. The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling. European Archives of Oto-Rhino-Laryngology. 2024;281(1):141-151. doi:10.1007/s00405-023-08103-9

BibTeX
@article{Dejaco2024,
  author = {Dejaco, Daniel and Riedl, David and Gottfried, Timo Maria and Santer, Matthias and Runge, Annette and Seebacher, Josef and Zelger, Philipp and Lia, Bicego and Joachim, Schmutzhard},
  title = {The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2024},
  volume = {281},
  number = {1},
  pages = {141--151},
  doi = {10.1007/s00405-023-08103-9}
}
Kostenlos starten →