A double-channel gastroscope (DCG) facilitates transgastric peritoneoscopy as salvage of Type I stent misdeployment (SMD-I) during EUS-guided gastroenterostomy (EUS-GE)

M. Cobreros del Caz, M. De Benito Sanz, A. Martinez-Ortega, R. Sánchez-Ocaña, C. De La Serna Higuera, M. Perez-Miranda

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S439

DOI: 10.1055/s-0044-1783803 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. Cobreros del Caz und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Text Introduction: Overall SMD rate during EUS-GE is 10%. Case: Advanced stage-IV colo-rectal cancer resulting in gastric-outlet obstruction. SMD-I occurs during attempted EUS-GE. The misdeployed LAMS is used as internal trocar for passage of DCG from stomach into peritoneum. By injecting contrast+methylene-blue through previous oro-jejunal catheter, the target jejunum is identified by fluoroscopy at peritoneoscopy. A grasping forceps through DCG holds jejunum in place while needle-knife incision grants guidewire access for insertion of a bridging LAMS. Distal flange dislodgment of 2nd LAMS during gastric retraction is fixed by re-sheathing, re-deployment, and placement of a 3rd longer bridging stent. Comment: DCG stabilizes jejunum facilitating incision access at peritoneoscopy to fix SMD-I. Video http://data.process.y-congress.com/ScientificProcess/Data//106/474/1197/e2ec8aee-4341-4481-8cef-0a4f53da6453/Uploads/13821_ESGE_24_Rescate_GYUSE.mov Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Caz, M. C. D., Sanz, M. D. B., Martinez-Ortega, A., Sánchez-Ocaña, R., Higuera, C. D. L. S., & Perez-Miranda, M. (2024). A double-channel gastroscope (DCG) facilitates transgastric peritoneoscopy as salvage of Type I stent misdeployment (SMD-I) during EUS-guided gastroenterostomy (EUS-GE). Endoscopy, 56(S 02 S 02), S439. https://doi.org/10.1055/s-0044-1783803

Vancouver

Caz MCD, Sanz MDB, Martinez-Ortega A, Sánchez-Ocaña R, Higuera CDLS, Perez-Miranda M. A double-channel gastroscope (DCG) facilitates transgastric peritoneoscopy as salvage of Type I stent misdeployment (SMD-I) during EUS-guided gastroenterostomy (EUS-GE). Endoscopy. 2024;56(S 02 S 02):S439. doi:10.1055/s-0044-1783803

BibTeX
@article{Caz2024,
  author = {Caz, M. Cobreros del and Sanz, M. De Benito and Martinez-Ortega, A. and Sánchez-Ocaña, R. and Higuera, C. De La Serna and Perez-Miranda, M.},
  title = {A double-channel gastroscope (DCG) facilitates transgastric peritoneoscopy as salvage of Type I stent misdeployment (SMD-I) during EUS-guided gastroenterostomy (EUS-GE)},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S439},
  doi = {10.1055/s-0044-1783803}
}
Kostenlos starten →