EUVIMEDEUVIMED entdecken
Crossref

EUS-Guided Fine-Needle-Biopsy of Solid Lesions Using a 22G Needle – One size fits all?

M. Mirchev, M. Peruhova, I. Boeva, V. Stoitsov

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S400

DOI: 10.1055/s-0044-1783694 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. Mirchev und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To analyze the capability of a 22G multi-blade three-prong needle to provide a reliable core tissue for histological analysis from solid abdominal and mediastinal tumors and to compare it in pancreatic versus non-pancreatic tumors.

Methods

All patients were examined using the Olympus GF-UCT 180 linear echoendoscope and the Hitachi Aloka 750 ultrasound system. Every abdominal and mediastinal lesion was characterized by its size, location, vessel proximity and was sampled by a 22G needle of same size and characteristics. If the initial needle pass with 10-15 forth and back movements and `slow pull` of stylet was unsuccessful in providing a good core tissue for histology, a second pass was performed. Samples were sent for histopathological analysis. Indecisive cases were immunohistochemically stained in addition to hematoxylin-eosin.

Results

Sixty-six samples from 60 patients were included in the study. Of them 26 (39.4%) were female, the mean age was 67.2±14.2 years. The sampled lesions were as follows: pancreas-35; lymph nodes-7; gastric wall-6; liver-5; mediastinum-3; intraabdominal-3; adrenal gland-2; kidney-1; esophagus-1; gastroesophageal junction-1, papilla-1; retroperitoneum-1. Sufficient histology providing final diagnosis was present in 54 (81.8%) of them. Indecisive diagnosis was observed in 25 (37.9%) of the cases, all of them 25 (100%) provided sufficient tissue for immunohistochemical analysis which helped in establishing a final diagnosis. There was a trend towards a more frequent presece of a non-diagnostic tissue in non-pancreatic vs pancreatic tumors (6 (19.4%) vs 6 (17.1%)) but the difference was statistically insignificant (OR 1.16 95% CI 0.33-4.06, p=0.82).

Conclusions

A 22G FNB needle can provide sufficient tissue for diagnosis of solid tumors irrespective of their location. The samples are of good quality both for standard hematoxylin-eosin staining and for immunohistochemical analysis. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Mirchev, M., Peruhova, M., Boeva, I., & Stoitsov, V. (2024). EUS-Guided Fine-Needle-Biopsy of Solid Lesions Using a 22G Needle – One size fits all?. Endoscopy, 56(S 02 S 02), S400. https://doi.org/10.1055/s-0044-1783694

Vancouver

Mirchev M, Peruhova M, Boeva I, Stoitsov V. EUS-Guided Fine-Needle-Biopsy of Solid Lesions Using a 22G Needle – One size fits all?. Endoscopy. 2024;56(S 02 S 02):S400. doi:10.1055/s-0044-1783694

BibTeX
@article{Mirchev2024,
  author = {Mirchev, M. and Peruhova, M. and Boeva, I. and Stoitsov, V.},
  title = {EUS-Guided Fine-Needle-Biopsy of Solid Lesions Using a 22G Needle – One size fits all?},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S400},
  doi = {10.1055/s-0044-1783694}
}
Kostenlos starten →