Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of extraintestinal solid lesions: diagnostic value and safety in one single german center
Endoscopy · 01.04.2023 · 55 (S 02 S 02) · S301
DOI: 10.1055/s-0043-1765835 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2023. Verfasst von L. Schweiger-Hammelsbeck und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of solid extraintestinal lesions is an established standard procedure in daily routine. The goal of this study was to investigate how representative the obtained material is and how often complications occur.
Methods
Over the course of 36 months all patients with EUS-FNB of solid extraintestinal lesions in our teaching hospital were included.In addition to histologic and cytologic results,complications and needle size were assessed.
Results
A total of 118 FNBs were performed in the 116 patients included (mean age 66 years, 47% women). Of these, 79 (67%) were pancreatic lesions, 22 (19%) lymph nodes and 17 (14%) other solid extraintestinal lesions from the upper/lower gastrointestinal tract.FNB revealed representative material in 82% of pancreatic lesions, 91% of lymph nodes, and in 82% in other lesions. Final diagnosis was pancreatic carcinoma in 28% (n=33), NET in 6% (n=7), metastases in 6% (n=7), other carcinomas in 13% (n=15) and cystadenomas in 10% (n=12).Simultaneous histologic and cytologic evaluation was performed in 80 FNBs (68%). Of these, the diagnosis was made in both workups in 54% (n=43), in histology alone in 21% (n=17), and in no case in cytology alone.Complications occurred in 2 cases (one non-Hb relevant hemorrhage, one pancreatitis). On average, 1.6 FNBs were performed. Mainly a 22G needle (53%) followed by a 19G needle (21%) was used.
Conclusions
EUS-FNB is a good and safe procedure in the diagnosis of solid extraintestinal lesions. In our setting, cytologic workup seems dispensable if histologic examination has been performed. Publication History Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Schweiger-Hammelsbeck, L., Schorr, W., Brookman-Amissah, D., Baumer, S., Pfeifer, L., & Pech, O. (2023). Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of extraintestinal solid lesions: diagnostic value and safety in one single german center. Endoscopy, 55(S 02 S 02), S301. https://doi.org/10.1055/s-0043-1765835
Vancouver
Schweiger-Hammelsbeck L, Schorr W, Brookman-Amissah D, Baumer S, Pfeifer L, Pech O. Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of extraintestinal solid lesions: diagnostic value and safety in one single german center. Endoscopy. 2023;55(S 02 S 02):S301. doi:10.1055/s-0043-1765835
BibTeX
@article{SchweigerHammelsbeck2023,
author = {Schweiger-Hammelsbeck, L. and Schorr, W. and Brookman-Amissah, D. and Baumer, S. and Pfeifer, L. and Pech, O.},
title = {Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of extraintestinal solid lesions: diagnostic value and safety in one single german center},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {S 02 S 02},
pages = {S301},
doi = {10.1055/s-0043-1765835}
}
EUVIMED