Optimising EUS-FNB guided tissue acquisition: The significance of TRAP score in solid pancreatic and gastrointestinal lesions for positive diagnostic output
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S380-S381
DOI: 10.1055/s-0044-1783638 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von S. Karim und 2 weiteren Autor:innen. Die Arbeit nennt 1 Literaturangaben.
Abstract (Originalsprache)
Aims
Endoscopic ultrasound-guided FNB tissue acquisition (EUS-FNB-TA) has revolutionized diagnostic approaches in gastroenterology related solid lesions. Accurate lesion localization, needle gauge, rapid on-site evaluation (ROSE), effective tissue core (>4mm) size, effective number of needles passes (such as>2 passes) are the requirement for the successful output. Furthermore, advanced age especially>60 also considered a risk factor for GI related malignancies. Keeping this in view, the Purpose or AIM of this study was to develop the tool/score based on the important factors responsible for higher number of positive EUS-FNB-TA output.
Methods
This is a retrospective study, conducted at the gastroenterology-department of Liaquat National Hospital, Karachi, Pakistan. Data collection duration was Jan-2019 to July-2023, after asking institutional permission. It included all consecutive data of gastrointestinal/pancreatic EUS-FNB from departmental Electronic Medical Record (EMR). Abandoned procedures data were excluded. A TRAP score/tool was developed. It included four parameters such as Tissue size (T, 1=>4mm and 0= 2 passes and 0=2 and 60 years, in 86.9% with>2 needle passes, in 88.9% of tissue size>4mm, in 93.1% of ROSE positive. Median TRAP score was 3 (IQR=2-4). ROC curve showed an AUC of 0.961 with statistical significance. At threshold of 3 and above, sensitivity, specificity was 83.3%, 100%, while positive predictive and negative predictive value were 100% and 73.1% respectively.
Conclusions
TRAP score can be useful tool for the predictability of higher EUS-FNB-TA positive output in gastrointestinal and pancreatic solid lesions. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Karim, S., Kadir, S., & Faryal, A. (2024). Optimising EUS-FNB guided tissue acquisition: The significance of TRAP score in solid pancreatic and gastrointestinal lesions for positive diagnostic output. Endoscopy, 56(S 02 S 02), S380-S381. https://doi.org/10.1055/s-0044-1783638
Vancouver
Karim S, Kadir S, Faryal A. Optimising EUS-FNB guided tissue acquisition: The significance of TRAP score in solid pancreatic and gastrointestinal lesions for positive diagnostic output. Endoscopy. 2024;56(S 02 S 02):S380-S381. doi:10.1055/s-0044-1783638
BibTeX
@article{Karim2024,
author = {Karim, S. and Kadir, S. and Faryal, A.},
title = {Optimising EUS-FNB guided tissue acquisition: The significance of TRAP score in solid pancreatic and gastrointestinal lesions for positive diagnostic output},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S380--S381},
doi = {10.1055/s-0044-1783638}
}
EUVIMED