EUVIMEDEUVIMED entdecken
Crossref

An investigation into the materials and life-cycle assessment of supplies commonly used in colonoscopy

M. García-Castellanos, V. Lorenzo-Zúñiga, S. Gayam, R. Martín-Cabezuelo, G. Vilariño-Ferrer, P. López-Muñoz, I. Tort-Ausina, K. A. Smolen, N. Ayer, A. Vidaurre-Garayo, A. Campillo, V. Pons-Beltrán und 1 weitere

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S184

DOI: 10.1055/s-0044-1783102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. García-Castellanos und 12 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

GI endoscopy is highly resource-intensive with a significant environmental impact and extensive utilization of non-reusable plastic instruments. Colonoscopy is the most commonly performed gastrointestinal procedure. The type of material has a direct effect on the environmental impact and on carbon emission. We aimed to scrutinize the materials commonly employed in colonoscopy procedures, assessing their life cycle (LCA) by determining their carbon footprint.

Methods

We examined supplies commonly used for colonoscopy procedures, not taking in account diagnostic or therapeutic supplies (e.g. forceps or snares), and reprocessing, were categorized according to procedure stage: i) Pre-procedure (iv needle, iv dressing, EKG leads, BP cuff, nasal cannula and underpad) and ii) Procedure room (gloves, syringe, three-way trap, infusion extension tube, suction container, aspiration tube and tubing). These materials were categorized based on their primary components, which were subjected to Fourier Transform Infrared Spectroscopy (FTIR) and Thermogravimetric Analysis (TGA), ultimately disclosing their composition. Carbon footprint (kgCO 2 e) from production, transportation and end-of-life will be calculated with an OpenLCA software (in progress).

Results

The total waste of examined colonoscopy supplies was 249.5 g (pre-procedure/procedure room): landfill waste 27 g (10.82%), regulated medical waste 185.5 g (74.35%), recycled paper 10 g (4.01%) and recycled plastic 27 g (10.82%) kg. Primary components of different supplies were identified as polymeric, being polyethylene (PE, 88 g), acrylonitrile butadiene (AB, 37 g) and polytetrafluoroethylene (PTFE, 34 g) those with high weight content. Metallic materials were almost negligible being brass the only one detected.

Conclusions

Understanding the nature of the materials used in colonoscopy and their environmental impact should be a contemporary priority to select the most sustainable alternative among various commercial brands. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

García-Castellanos, M., Lorenzo-Zúñiga, V., Gayam, S., Martín-Cabezuelo, R., Vilariño-Ferrer, G., López-Muñoz, P., Tort-Ausina, I., Smolen, K. A., Ayer, N., Vidaurre-Garayo, A., Campillo, A., Pons-Beltrán, V., & Pohl, H. (2024). An investigation into the materials and life-cycle assessment of supplies commonly used in colonoscopy. Endoscopy, 56(S 02 S 02), S184. https://doi.org/10.1055/s-0044-1783102

Vancouver

García-Castellanos M, Lorenzo-Zúñiga V, Gayam S, Martín-Cabezuelo R, Vilariño-Ferrer G, López-Muñoz P, et al. An investigation into the materials and life-cycle assessment of supplies commonly used in colonoscopy. Endoscopy. 2024;56(S 02 S 02):S184. doi:10.1055/s-0044-1783102

BibTeX
@article{GarcaCastellanos2024,
  author = {García-Castellanos, M. and Lorenzo-Zúñiga, V. and Gayam, S. and Martín-Cabezuelo, R. and Vilariño-Ferrer, G. and López-Muñoz, P. and Tort-Ausina, I. and Smolen, K. A. and Ayer, N. and Vidaurre-Garayo, A. and Campillo, A. and Pons-Beltrán, V. and Pohl, H.},
  title = {An investigation into the materials and life-cycle assessment of supplies commonly used in colonoscopy},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S184},
  doi = {10.1055/s-0044-1783102}
}
Kostenlos starten →