Variability in Computer-Aided Detection effect on Adenoma Detection Rate in randomized controlled trials: a meta-regression analysis
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S145
DOI: 10.1055/s-0044-1783005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. Spadaccini und 20 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
The assistance of computer-aided detection (CADe) systems during colonoscopy may increase adenoma detection rate (ADR), theoretically reducing the risk of post-colonoscopy colorectal cancer (PCCRC). Although the promising results in different randomized trials, both the variability of the magnitude of relative effect of CADe systems across the previous studies, and the contradicting results in the first real-life experiences, highlighted a clear gap of knowledge when looking for those factors possibly explaining these fluctuating results. The aim of our analysis was to investigate the different variables possibly affecting the impact of CADe-assisted colonoscopy and its effect on ADR.
Methods
We searched MEDLINE, EMBASE, and Scopus databases until July 2023 for RCTs reporting diagnostic accuracy of CADe systems in the detection of colorectal neoplasia (PROSPERO: CRD42023462438). The main outcome was pooled adenoma detection rate (ADR). We calculated risk ratios (RRs), and performed meta-regression analysis to explore thesources of heterogeneity. The variables examined included factors with an impact on expected prevalence of adenomas across the study populations, such as gender, age and colonoscopy indication. We also included both key (ADR), and minor (Withdrawal time) performance measures considered as quality indicators for colonoscopy.
Results
Twenty-three randomized controlled trials (RCTs) on 19,077 patients were include. ADR was higher in the CADe group than in the standard colonoscopy group (45.83% versus 38.28%; RR 1.22 [95% CI 1.14-1.29]) with substantial level of heterogeneity (I 2 =67.69%). In univariable meta-regression analysis, patient age, ADR in control arms, and withdrawal time were the strongest predictors of CADe effect on ADR (P
Zitieren
APA
Spadaccini, M., Yuichi, M., Hassan, C., Antonio, F., Rizkala, T., Massimi, D., Roberta, M., Patel, H., Kareem, K., Ramai, D., Emanuele, R., Radaelli, F., Fugazza, A., Colombo, M., Alessandro, D. M., franchellucci, G., Rex, D. K., Abdelrahim, M., Pradeep, B., …, & Repici, A. (2024). Variability in Computer-Aided Detection effect on Adenoma Detection Rate in randomized controlled trials: a meta-regression analysis. Endoscopy, 56(S 02 S 02), S145. https://doi.org/10.1055/s-0044-1783005
Vancouver
Spadaccini M, Yuichi M, Hassan C, Antonio F, Rizkala T, Massimi D, et al. Variability in Computer-Aided Detection effect on Adenoma Detection Rate in randomized controlled trials: a meta-regression analysis. Endoscopy. 2024;56(S 02 S 02):S145. doi:10.1055/s-0044-1783005
BibTeX
@article{Spadaccini2024,
author = {Spadaccini, M. and Yuichi, M. and Hassan, C. and Antonio, F. and Rizkala, T. and Massimi, D. and Roberta, M. and Patel, H. and Kareem, K. and Ramai, D. and Emanuele, R. and Radaelli, F. and Fugazza, A. and Colombo, M. and Alessandro, D. M. and franchellucci, G. and Rex, D. K. and Abdelrahim, M. and Pradeep, B. and Prateek, S. and Repici, A.},
title = {Variability in Computer-Aided Detection effect on Adenoma Detection Rate in randomized controlled trials: a meta-regression analysis},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S145},
doi = {10.1055/s-0044-1783005}
}
EUVIMED